RVV 700 Standard Programming Service and Parts Manual
SECTION 3: Vender Programming
At the “Go to Selection” prompt, press <enter>. “Go to
Selection” will be highlighted on the display. To assign
cells to a selection number, key in the number of the
selection using the keypad, then press <enter>. A list of all
cells within the vender will be shown, accompanied by the
following information:
• If the cell is currently assigned to the entered selection
number (shown at the top of the display), a checked box
will follow the cell number. To unassign this cell, press
<enter>, and the box will be empty.
• If the cell is currently assigned to another selection, but
not the entered selection number, “Selection NN” will
follow the cell number (where “NN” is the number of the
selection). To assign this cell to the current selection, press
<enter>.
• If the cell is currently unassigned to any selection, an
unmarked box will appear.
Pressing <up> or <down> will scroll the display through
each individual cell number. Once all desired cells have
been assigned to the entered selection, press <exit>. The
display will return to the highlighted “Go to Selection”
prompt. Type in another selection number to enter into it.
Once all selections have been assigned as desired, press
<exit> from the “Go to Selection” prompt. The display
will show “Save?”. Press <enter> to save the new settings
and return the display to the “Custom” prompt.
Notes: Selection pricing must be aligned with the space-
to-sales assignments.
Vend Evenly
If <enter> is pressed at “Vend Evenly”, the check box
will be toggled between checked (all cells tied together in
space-to-sales will alternate vending for even distribution)
or unchecked (each cell will be vended until empty before
product is dispensed from the next tied cell).
Set Package Sizes
If <enter> is pressed at the “Set Package Sizes” prompt,
the controller will enter the package setting mode. This
mode is used to adjust selections to vend certain small
packages reliably. Using <up> or <down> will allow you
to cycle through the various options for setting package
size (“All”, “Shelf”, or “Cell”). For each option, three
package size selections are available: Small, Standard, or
Large.
All
If <enter> is pressed at “All”, this line will be highlighted,
and the package size for all cells can be set at once. Press
<up> or <down> to change the universal size. Once the
desired package size is shown, press <enter> to save it and
return the display to the unhighlighted state. Use <up>
to proceed to the next option, “Shelf”, or press <exit> to
return to the “Set Package Sizes” prompt.
Shelf
If <enter> is pressed at “Shelf”, each shelf number will
be displayed, followed by the current universal package
size for the shelf. Press <up> or < down> to cycle through
each individual shelf number. If <enter> is pressed at a
particular shelf number, that shelf and its current package
size setting will be highlighted. Use <up> or <down> to
change this size. Once the desired package size is shown,
press <enter> to save it and return the display to the
unhighlighted state. Once all shelves’ package sizes have
been set, press <exit> to return to the “Shelf” prompt.
Press <up> to proceed to the next option, “Cell”.
If <enter> is pressed at “Cell”, each cell number will be
displayed, followed by its current package size setting.
Press <up> or < down> to cycle through each individual
cell number. If <enter> is pressed at a particular cell
number, that cell and its current package size setting
will be highlighted. Press <up> or <down> to change
this setting. Once the desired package size is shown,
press <enter> to save it and return the display to the
unhighlighted state. Press <exit> to return to the “Cell”
prompt, then press <exit> a second time to return to the
“Set Package Sizes” prompt. Press <up> to proceed to the
next available prompt, “Configurations”.
Содержание RVV 700
Страница 4: ...RVV 700 Standard Programming Service and Parts Manual 4 TABLE OF CONTENTS continued...
Страница 18: ...RVV 700 Standard Programming Service and Parts Manual 18 SECTION 2 Vender Component Explanation...
Страница 42: ...RVV 700 Standard Programming Service and Parts Manual 42 SECTION 5 Troubleshooting...
Страница 43: ...43 RVV 700 Standard Programming Service and Parts Manual SECTION 5 Troubleshooting...
Страница 47: ...47 RVV 700 Standard Programming Service and Parts Manual SECTION 6 Parts Catalog RVV 700 Cup Assembly 854048...
Страница 50: ...RVV 700 Standard Programming Service and Parts Manual 50 SECTION 6 Parts Catalog Elevator Cup Assembly 408821...
Страница 51: ...51 RVV 700 Standard Programming Service and Parts Manual SECTION 6 Parts Catalog Guide Rail Assembly 854079...
Страница 65: ...65 RVV 700 Standard Programming Service and Parts Manual SECTION 6 Parts Catalog RVV 700 Port Assembly 854078...
Страница 74: ...RVV 700 Standard Programming Service and Parts Manual 74 Wiring Schematic...
Страница 75: ...75 RVV 700 Standard Programming Service and Parts Manual Wiring Schematic...