RVV 700 Standard Programming Service and Parts Manual
22
SECTION 3: Vender Programming
System Info
If <enter> is pressed at the “System Info” prompt, the
current system information will be displayed, as follows:
Time (displays current day, date, and time)
Machine Model No.
Machine Serial No.
VMC Model No.
VMC Serial No.
Boot Loader
Version
Cup
Port
If the <enter> or <exit> buttons are pressed anytime during
this operation, the controller will return to the “System
Info” prompt. Press the <down> button to proceed to the
next prompt, “Tube Fill”.
Tube Fill
If <enter> is pressed at the “Tube Fill” prompt, the
controller will enter the tube fill mode, and “Tube
Fill” will be highlighted. This mode allows any coin
that is routed to a tube to be deposited, providing total
accountability. The tube inventory level for the deposited
coin will be displayed after the coin is accepted. If a tube
full status is detected, that coin will no longer be accepted.
During this entire operation, MIS tube counts will be
updated accordingly. If <exit> is pressed at any time, the
controller will return to the unhighlighted “Tube Fill”
prompt. Press <down> to proceed to the next prompt,
“Coin Payout”.
Coin Payout
If <enter> is pressed at the “Coin Payout” prompt, the
controller will enter the coin payout routine. “Coin
Payout” will be highlighted, along with the lowest-
available coin tube value. Pressing <enter> when a
particular coin value is displayed will pay out the
displayed coin type at half-second intervals until the
button is released, and the display will show the coin value
followed by the quantity of times paid out. Press <up> or
<down> will scroll to the next available coin tube value.
All coins dispensed in this mode are counted in the MIS
tube counts and the manual dispense mode counters. If
<exit> is pressed at any time, the controller will return to
the unhighlighted “Coin Payout” prompt. Press <down> to
proceed to the next prompt, “Test Modes”.
Test Modes
If <enter> is pressed at the “Test Modes” prompt, the
controller will enter the test modes. Using <up> or
<down> will allow you to cycle through the available tests.
If <exit> is pressed at any time, the controller will return
to the “Test Modes” prompt. Use <down> to proceed
to the next prompt, “Enter Password” (if the password
has not already been entered) or “Cash Counters” (if the
password has been entered).
• Test Vend
If <enter> is pressed at the “Test Vend” prompt, the
controller will enter the test vend routine. This routine
will allow the operator to test the functionality of the
vending mechanism and of the individual cells. “Test
Vend”, followed by “All”, will be highlighted. To
test a selection, type in the desired selection number
using the vender’s keypad. Pressing <enter> or “0”
at “All” will cause a sequential vend from cell 10 all
the way to the last cell. Press <exit> to return to the
unhighlighted “Test Vend” prompt. Press <down> to
proceed to the next prompt, “Test Selection Switches”.
• Test Selection Switches
If <enter> is pressed at the “Test Selection Switches”
prompt, the controller will enter the selection switch
test mode. This mode tests the functionality of the
keypad. The display will be highlighted, showing
“Test Selection Switches #”, the switch number of
the <enter> key. With each subsequent press of a
key, the display will show that particular key number
on the display. Keys labeled 1-9 are displayed as
“1” to “9”; the 0 and # keys are displayed as “11”
and “12,” respectively. To exit the selection switch
test mode, press the <exit> key. (Doing so will also
test the functionality of the * key.) This will return
the controller to the unhighlighted “Test Selection
Switches” prompt. Press <down> to proceed to the
next prompt, “Test Display”.
• Test Display
Pressing <enter> at the “Test Display” prompt will
cause the controller to enter the display test routine.
This routine allows you to test the display. Upon entry
into this routine, the display will light up in successive
bands of red, green, and blue. The test will continue
indefinitely until <exit> is pressed, at which time the
controller will return to the “Test Display” prompt.
Press <down> to proceed to the next prompt, “Test
Relays”.
Содержание RVV 700
Страница 4: ...RVV 700 Standard Programming Service and Parts Manual 4 TABLE OF CONTENTS continued...
Страница 18: ...RVV 700 Standard Programming Service and Parts Manual 18 SECTION 2 Vender Component Explanation...
Страница 42: ...RVV 700 Standard Programming Service and Parts Manual 42 SECTION 5 Troubleshooting...
Страница 43: ...43 RVV 700 Standard Programming Service and Parts Manual SECTION 5 Troubleshooting...
Страница 47: ...47 RVV 700 Standard Programming Service and Parts Manual SECTION 6 Parts Catalog RVV 700 Cup Assembly 854048...
Страница 50: ...RVV 700 Standard Programming Service and Parts Manual 50 SECTION 6 Parts Catalog Elevator Cup Assembly 408821...
Страница 51: ...51 RVV 700 Standard Programming Service and Parts Manual SECTION 6 Parts Catalog Guide Rail Assembly 854079...
Страница 65: ...65 RVV 700 Standard Programming Service and Parts Manual SECTION 6 Parts Catalog RVV 700 Port Assembly 854078...
Страница 74: ...RVV 700 Standard Programming Service and Parts Manual 74 Wiring Schematic...
Страница 75: ...75 RVV 700 Standard Programming Service and Parts Manual Wiring Schematic...