RVV 700 Standard Programming Service and Parts Manual
SECTION 3: Vender Programming
• Bill Validator
By pressing <enter> at the “Bill Validator” prompt,
the controller will display either:
1. “Bill Val Comm,” indicating no bill validator
communications for more than 5 seconds;
2. “Bill Stacker Full,” indicating a full bill stacker;
3.
“Bill Motor,” indicating a defective motor;
4. “Bill Jam,” indicating a bill jam error;
5.
“Bill Val ROM,” indicating a bill acceptor ROM
check sum error;
6. “Open Cash Box,” indicating an open cash box;
or
7. “Bill Sensor,” indicating a bill sensor error.
The “Bill Val Comm” error will be cleared when
proper communications are re-established. After
taking corrective action to manually fix the other
“Bill Validator” problems, the errors may be cleared
electronically via a hand-held device or through the
service mode using the <clear> button.
• Card Reader
By pressing <enter> at the “Card Reader” prompt, the
controller will display either:
1. “Card Reader Comm,” indicating no card reader
communications for more than 5 seconds; or
2. “Card Reader Error XY,” indicating that a
particular type of card reader malfunction
occurred where “XY” indicates the error type.
The “Card Reader Comm” error will be cleared when
proper communications are re-established. The “Card
Reader Error XY” errors may be reset via the hand-
held device or through the service mode using the
<clear> button.
• Vend Mechanism
By pressing <enter> at the “Vend Mechanism”
prompt, the controller will display either:
1. “Delivery System,” indicating that there is a
generic vend mechanism error;
2. “Cup Sensor,” indicating that the cup sensor has
malfunctioned;
3. “Home Sensor,” indicating that the home sensor
has malfunctioned;
4. “Critical Mech,” indicating a critical vend
mechanism error has occurred;
5. “Delivery Port Sense,” indicating that the VMC is
reporting a port sense error; or
6. “Delivery Port Door,” indicating that the VMC is
reporting a port door error.
After taking corrective action to manually fix the
“Vend Mechanism” errors, the errors may be cleared
electronically via a hand-held device or through the
service mode using the <clear> button.
• Space to Sales
By pressing <enter> at the “Space to Sales” prompt,
the controller will display “Unassigned Cell XX,”
indicating that cell XX is unassigned. These errors
are cleared when new space to sales programming
resolves the errors or via the service mode using the
<clear> button. (Note: When an unassigned cell is
selected in the sales mode, the display will show “No
Sales Available.”)
• Refrigeration
By pressing <enter> at the “Refrigeration” prompt, the
controller will display either:
1. “Temperature Sensor,” indicating an unplugged
temperature sensor error;
2. “Temperature Too Cold,” indicating temperatures
3º F (1.5º C) below the compressor cut-out
setting;
3. “Temperature Too Hot,” indicating temperatures
3º F (1.5º C) above the compressor cut-in setting;
4. “Compressor,” indicating that the compressor
is not cooling at 1º F (0.5º C) per hour or better
while on;
5. “Heater,” indicating that the heating system is not
heating at 1º F (0.5º C) per hour or better while
on;
6. “Not Cooling,” indicating an inability to reach the
set point temperature; or
7. “Health Safety Failed,” indicating that the health
safety limit temperature has been violated.
The “Temperature Sensor” error will be cleared if
the sensor is detected. The “Temperature Too Cold”
error will be cleared when the temperature rises above
the cut-out limit. The “Temperature Too Hot” error
will be cleared when the temperature falls below the
cut-in limit. The “Compressor” error will be cleared
when the system cools at 1º F (0.5º C) per hour or
better. The “Heater” error will be cleared when
the system heats at 1º F (0.5º C) per hour or better.
The “Not Cooling” error must be manually cleared
electronically via a hand-held device or through the
service mode using the <clear> button. All other
“Refrigeration” errors can also be cleared via the
hand-held device or through service mode using the
<clear> button.
Содержание RVV 700
Страница 4: ...RVV 700 Standard Programming Service and Parts Manual 4 TABLE OF CONTENTS continued...
Страница 18: ...RVV 700 Standard Programming Service and Parts Manual 18 SECTION 2 Vender Component Explanation...
Страница 42: ...RVV 700 Standard Programming Service and Parts Manual 42 SECTION 5 Troubleshooting...
Страница 43: ...43 RVV 700 Standard Programming Service and Parts Manual SECTION 5 Troubleshooting...
Страница 47: ...47 RVV 700 Standard Programming Service and Parts Manual SECTION 6 Parts Catalog RVV 700 Cup Assembly 854048...
Страница 50: ...RVV 700 Standard Programming Service and Parts Manual 50 SECTION 6 Parts Catalog Elevator Cup Assembly 408821...
Страница 51: ...51 RVV 700 Standard Programming Service and Parts Manual SECTION 6 Parts Catalog Guide Rail Assembly 854079...
Страница 65: ...65 RVV 700 Standard Programming Service and Parts Manual SECTION 6 Parts Catalog RVV 700 Port Assembly 854078...
Страница 74: ...RVV 700 Standard Programming Service and Parts Manual 74 Wiring Schematic...
Страница 75: ...75 RVV 700 Standard Programming Service and Parts Manual Wiring Schematic...