background image

  fReSCaPURe

  

13

  

  sysTem insTallaTion:

Read these instructions completely before starting system Installation 

Make a determination whether you will be able to make a “Typical” installation

  

(as shown in the illustration on page 10) 

after looking at your under-sink  

cabinet area.

 

If the configuration of your under-sink area does not permit a “Typical”  
installation, it will be necessary to develop one of your own. Be sure to  
take into consideration where the System will be permanently located in 
relationship to the cold water supply line and Dedicated Drinking Water Faucet. 
Make generous allowances for estimating the Tubing lengths required to 
make these connections. 

(Two Velcro Strips have been provided should you 

decide to mount the Monitor to the cabinet wall.)

   Before starting this installation, be certain to 

turn “OFF” the cold water supply located under 
your sink. If a shut-off valve is not located on 
the cold water supply line, shut off the main 
water supply to your home.

   Locate an area under sink to place the Base. 

The Base should be located directly under 
the area where the Dedicated Drinking Water 
Faucet is installed.

   Locate the shut-off valve on the existing cold 

water supply line. Using a 5/8” open ended 
wrench, unthread compression nut located  
on top of the shut-off valve by turning the 
wrench counterclockwise. 

   Thread the T-Valve onto shut-off valve using  

a 3/4” wrench to tighten, then thread  
compression nut onto T-Valve using 5/8” 
wrench to tighten

 (clockwise)

.

  Before pushing the White Tubing 

(which is  

attached to the Dedicated Drinking Water 
Faucet)

 into the “Outlet” Collar located on  

T-Valve, determine whether it is necessary  
to shorten Tubing. If so, shorten to desired  
length before inserting.

 

4

3

5

WARNING

 

Do not use copper tubing with the Collars installed on this System. 

although it may appear that copper tubing will fit, water leaks will develop over time. 

If copper tubing is required, you must use copper compression fittings that must be 

purchased separately and adapted accordingly.

Содержание FP6000CT

Страница 1: ...IMPORTANT Read and Save these Instructions Questions or Comments 1 800 279 3373 8am 5pm Central Standard Time Use Care Manual Water filtration systems MODELS FP6000CT FP6000UC...

Страница 2: ...rtridge Countertop System 6 Installation Under Counter System Model FP6000UC 9 DRILLING A HOLE IN A STAINLESS STEEL SINK 10 DRILLING A HOLE IN A PORCELAIN CERAMIC SINK 11 Faucet Installation 12 System...

Страница 3: ...hing RED indicating the rated capacity has been reached When the flow rate diminishes When you notice a taste or odor recurrence 3 Do not use with water that is microbiologically unsafe or of unknown...

Страница 4: ...use sanitary gloves to remove the Filter Cartridge Place Cartridge into clean plastic bag seal and refrigerate Once you return re install the Cartridge per the Replacement Instructions and continue to...

Страница 5: ...839 L Replacement Filter Cartridge WF0705 Monitor Electronic LED Rated Service Flow 60 psi 0 75 Gal min 2 84 L min Housing Construction 316 Surgical Stainless Steel Lid Construction High Impact ABS Ma...

Страница 6: ...3 RP6154 Housing Clamp includes Knob T Bolt 4 RP6155 Stainless Steel Filter Housing 5 RP6160 Base 6 RP6161 Faucet Kit includes 7 Dedicated Water Faucet 8 Monitored Beauty Ring 9 Rubber Washer 10 C Wa...

Страница 7: ...ucet Next thread the Diverter Valve to the Adapter 6 If your kitchen faucet does not have threads measure the inside diameter of your faucet and provide this information to your Independent Royal Pres...

Страница 8: ...re System is ready for use REPLACING THE Filter Cartridge Countertop System The most important part of maintaining your FrescaPure Drinking Water System is replacing the Cartridge on a regular service...

Страница 9: ...ockwise onto Lid until you feel resistance Make an additional quarter turn DO NOT over tighten 9 Make certain Gasket is firmly seated onto Lid With new Cartridge connected to Lid lower Cartridge into...

Страница 10: ...e Monitor Cable inside the Enclosure Hinge Cover to front of Enclosure as shown then press rear portion of Cover into place Position the System next to your sink 16 Slowly turn the cold water ON and t...

Страница 11: ...Drilling a Hole in a Stainless Steel Sink 3 8 Variable Speed Electric Drill 1 8 Drill Bit 1 Hole Saw Masking Tape Hammer Punch Installing the T Valve and Dedicated Drinking Water Faucet 5 8 and 3 4 Op...

Страница 12: ...ith masking tape Use the punch and hammer to make a light indentation at the designated faucet installation location 2 Using a 1 8 high speed drill bit drill a pilot hole in the sink 3 Use a 1 hole sa...

Страница 13: ...rill motor turning as slowly as possible after the initial cut has started in the porcelain the drill motor s R P M may be increased Avoid high R P M s during the initial penetration of the porcelain...

Страница 14: ...Cable through Rubber Washer and slide firmly onto Faucet Stem 4 Insert the Red White and Blue Tube ends through Nut and thread Nut onto Faucet Stem Insert the C Washer between Nut and Rubber Washer an...

Страница 15: ...e cold water supply line shut off the main water supply to your home 2 Locate an area under sink to place the Base The Base should be located directly under the area where the Dedicated Drinking Water...

Страница 16: ...ort located on Monitor 10 Slowly turn cold water supply ON and turn the Lever on Dedicated Drinking Water Faucet downward Water will begin filling the System Upon initial startup the Monitored Beauty...

Страница 17: ...t Lid upward This step will expose the Filter Cartridge 3 While holding Lid turn Cartridge counter clockwise to remove Wrap in newspaper and discard with normal refuse 4 Wash inside of Housing and Lid...

Страница 18: ...N and turn the Lever on Dedicated Drinking Water Faucet downward Water will begin filling the System Upon initial startup the Monitored Beauty Ring will begin blinking GREEN YELLOW and RED five 5 time...

Страница 19: ...FRESCAPURE 17 Notes...

Страница 20: ...ive amounts of particles in the water supply may have caused premature plugging of the Filter Cartridge SOLUTION The Cartridge and Battery Shuttle must be replaced due to poor water conditions in your...

Страница 21: ...UTION Press tube fitting firmly into Collar REASON 2 Tube end has been damaged elongated or not cut squarely SOLUTION Depress Collar using the Tool provided and pull Tube at the same time to remove Ob...

Страница 22: ...ARE LIMITED IN DURATION TO THE SAME DURATION AS THE WRITTEN WARRANTY DESCRIBED ABOVE FOR YOUR COVERED PRODUCT Some states do not allow limitations on how long an implied warranty lasts accordingly th...

Отзывы: