  fReSCaPURe

  

11

  dRillinG a hole in a PoRCelain/CeRamiC sink:

 

   Locate an area on your sink to install the  

Dedicated Drinking Water Faucet.

 (Make certain 

there are no support ribs under the sink in that 
area.)

 Cover the designated location for the 

Faucet installation on sink with masking tape.

   Using the carbide-tipped pilot drill supplied 

with the Relton Cutter Kit and a variable 
speed drill, slowly drill a pilot hole completely 
through the porcelain or enamel and metal 
base material.

   The plastic sleeve supplied on the pilot drill is 

to be positioned against the drill chuck after 
the pilot drill has been inserted. This prevents 
the drill chuck from contacting the porcelain 
after the pilot hole has been completed.

   Change to the spring-loaded porcelain saw 

bit. Be sure the pilot guide supplied is inserted 
tightly into the porcelain saw. With light  
pressure applied to the porcelain saw, start the 
drill motor turning as slowly as possible; after 
the initial cut has started in the porcelain, the 
drill motor’s R.P.M. may be increased. 

(Avoid 

high R.P.M.s during the initial penetration  
of the porcelain.)

 Three to four minutes may  

be necessary to cut the porcelain; a faster  
penetration rate could result in excessive  
chipping. Continue drilling until a complete 
ring has been cut through to the metal base.

   Change to the finish hole saw bit. Be sure the 

pilot guide is inserted tightly. Begin to cut with 
slow speed and light pressure until porcelain 

(inside the ring cut by porcelain saw in Step 4) 

has been penetrated to the metal underneath. 
At that point, remove the hole saw from the 
hole and clean all chips from the porcelain surface. Reinsert the hole saw 
into the hole and cut through the remaining material.

cAuTION

 

this type of sink can chip very easily. 

If you have any doubts about doing 

this yourself, consult a licensed plumber 

 

RecOMMeNdATION

 

 

experiment on discarded porcelain to familiarize yourself with 

the action and performance of the porcelain cutter kit.

3

4a

2a

5a

1

4b

2b

5b

Plastic Sleeve

Содержание FP6000CT

Страница 1: ...IMPORTANT Read and Save these Instructions Questions or Comments 1 800 279 3373 8am 5pm Central Standard Time Use Care Manual Water filtration systems MODELS FP6000CT FP6000UC...

Страница 2: ...rtridge Countertop System 6 Installation Under Counter System Model FP6000UC 9 DRILLING A HOLE IN A STAINLESS STEEL SINK 10 DRILLING A HOLE IN A PORCELAIN CERAMIC SINK 11 Faucet Installation 12 System...

Страница 3: ...hing RED indicating the rated capacity has been reached When the flow rate diminishes When you notice a taste or odor recurrence 3 Do not use with water that is microbiologically unsafe or of unknown...

Страница 4: ...use sanitary gloves to remove the Filter Cartridge Place Cartridge into clean plastic bag seal and refrigerate Once you return re install the Cartridge per the Replacement Instructions and continue to...

Страница 5: ...839 L Replacement Filter Cartridge WF0705 Monitor Electronic LED Rated Service Flow 60 psi 0 75 Gal min 2 84 L min Housing Construction 316 Surgical Stainless Steel Lid Construction High Impact ABS Ma...

Страница 6: ...3 RP6154 Housing Clamp includes Knob T Bolt 4 RP6155 Stainless Steel Filter Housing 5 RP6160 Base 6 RP6161 Faucet Kit includes 7 Dedicated Water Faucet 8 Monitored Beauty Ring 9 Rubber Washer 10 C Wa...

Страница 7: ...ucet Next thread the Diverter Valve to the Adapter 6 If your kitchen faucet does not have threads measure the inside diameter of your faucet and provide this information to your Independent Royal Pres...

Страница 8: ...re System is ready for use REPLACING THE Filter Cartridge Countertop System The most important part of maintaining your FrescaPure Drinking Water System is replacing the Cartridge on a regular service...

Страница 9: ...ockwise onto Lid until you feel resistance Make an additional quarter turn DO NOT over tighten 9 Make certain Gasket is firmly seated onto Lid With new Cartridge connected to Lid lower Cartridge into...

Страница 10: ...e Monitor Cable inside the Enclosure Hinge Cover to front of Enclosure as shown then press rear portion of Cover into place Position the System next to your sink 16 Slowly turn the cold water ON and t...

Страница 11: ...Drilling a Hole in a Stainless Steel Sink 3 8 Variable Speed Electric Drill 1 8 Drill Bit 1 Hole Saw Masking Tape Hammer Punch Installing the T Valve and Dedicated Drinking Water Faucet 5 8 and 3 4 Op...

Страница 12: ...ith masking tape Use the punch and hammer to make a light indentation at the designated faucet installation location 2 Using a 1 8 high speed drill bit drill a pilot hole in the sink 3 Use a 1 hole sa...

Страница 13: ...rill motor turning as slowly as possible after the initial cut has started in the porcelain the drill motor s R P M may be increased Avoid high R P M s during the initial penetration of the porcelain...

Страница 14: ...Cable through Rubber Washer and slide firmly onto Faucet Stem 4 Insert the Red White and Blue Tube ends through Nut and thread Nut onto Faucet Stem Insert the C Washer between Nut and Rubber Washer an...

Страница 15: ...e cold water supply line shut off the main water supply to your home 2 Locate an area under sink to place the Base The Base should be located directly under the area where the Dedicated Drinking Water...

Страница 16: ...ort located on Monitor 10 Slowly turn cold water supply ON and turn the Lever on Dedicated Drinking Water Faucet downward Water will begin filling the System Upon initial startup the Monitored Beauty...

Страница 17: ...t Lid upward This step will expose the Filter Cartridge 3 While holding Lid turn Cartridge counter clockwise to remove Wrap in newspaper and discard with normal refuse 4 Wash inside of Housing and Lid...

Страница 18: ...N and turn the Lever on Dedicated Drinking Water Faucet downward Water will begin filling the System Upon initial startup the Monitored Beauty Ring will begin blinking GREEN YELLOW and RED five 5 time...

Страница 19: ...FRESCAPURE 17 Notes...

Страница 20: ...ive amounts of particles in the water supply may have caused premature plugging of the Filter Cartridge SOLUTION The Cartridge and Battery Shuttle must be replaced due to poor water conditions in your...

Страница 21: ...UTION Press tube fitting firmly into Collar REASON 2 Tube end has been damaged elongated or not cut squarely SOLUTION Depress Collar using the Tool provided and pull Tube at the same time to remove Ob...

Страница 22: ...ARE LIMITED IN DURATION TO THE SAME DURATION AS THE WRITTEN WARRANTY DESCRIBED ABOVE FOR YOUR COVERED PRODUCT Some states do not allow limitations on how long an implied warranty lasts accordingly th...

Отзывы: