Subject to change.
Roto Patio Fold
IMO_374_EN_v1
April 2015
39
Installation
Drilling and routing dimensions
Notes on screw-fixing and drilling jig
6.2
Buffer-stop of
sash edge
Spacer for shadow-gap
adjustment 4 / 5 / 6 mm,
preset to 4 mm
Spacer for shadow-gap
adjustment 4 / 5 / 6 mm,
preset to 4 mm
Drill holes
Support bracket
Drill holes
Support bracket
Drilling insert
Frame / sash
hinge-bearing
Adjustment
SW 20 or SW 30
Adjust the hinge-fixing insert
if necessary
Adjustment insert
Hinge-fixing insert
NOTE!
The window fabricator must ensure adequate fixing of the hard-
ware components and correct load transfer. Recommendation:
Prove by DIN EN 13126-15, tests 7.2 and 7.3.
Screw-fixing through 2 profile walls
The wall-thickness of the first screwing level through aluminium must be
at least 2 mm.
If the wall-thickness of the first screwing level is < 2 mm, use supports or
riveting nuts in order to achieve a wall-thickness of at least 2 mm.
The wall-thickness of the second screwing level through aluminium must
be at least
1.6 mm
.
Screw-fixing through 1 profile wall
The wall-thickness of the first screwing level through aluminium must be
at least
6 mm
.
To achieve this, supports or riveting nuts must be used.
Содержание Patio Fold
Страница 2: ...2 April 2015 IMO_374_EN_v1 Roto Patio Fold Subject to change ...
Страница 32: ...32 April 2015 IMO_374_EN_v1 Roto Patio Fold Subject to change 13 Hardware overview Version enhanced threshold ...
Страница 35: ...Subject to change Roto Patio Fold IMO_374_EN_v1 April 2015 35 Hardware overview Parts list enhanced threshold ...
Страница 73: ...Subject to change Roto Patio Fold IMO_374_EN_v1 April 2015 73 Installation drawings Dimensions and positioning ...
Страница 89: ...Subject to change Roto Patio Fold IMO_374_EN_v1 April 2015 89 ...
Страница 90: ...90 April 2015 IMO_374_EN_v1 Roto Patio Fold Subject to change ...