10
Technical data
Refrigera
ting
capacity
Q
0
in W
at t
0
Type
Item no:
-30 °C
Power input P in W
Current consumption
I
N
in A
Electrical connection
Cooling agent / am
ount
of cooling agent
Defrosting
Dimensions in mm
L x W x H
Reducing inserts
Mass matter in kg
Nominal current of the
fuse to be superposed
Noise level
Protection class
Construction class N
Rofrost
1.1/4“
6.2200 /-Z
310 272
2,11
230 V±10
50 Hz ~
6
Rofrost
1.1/4“
6.2201
310 266
4,39
110 V
50 Hz ~
6
Rofrost
1.1/4“
6.2202
310 266
4,39
115 V
60 Hz ~
6
Rofrost 2”
6.2203 / -Z
310 272
2,11
230 V±10
50 Hz ~
4
Rofrost 2”
6.2204
310 266
4,39
110 V
50 Hz ~
4
Rofrost 2”
6.2205
310 266
4,39
115 V
60 Hz ~
4
Rofrost 2”
6.2206
310 272
2,11
230 V±10
50 Hz ~
R404A / 90g
Manual defrosting
500 x 253 x 315
10
25
10A
≤
50 dB(A)
IP 20 according to DIN 40050
Ambient temperature range +10...+32°C
Proper usage
The pipe freezing equipment must only be used to freeze
ROFROST TURBO: Copper pipes with a diameter of 10 – 42 mm or 3/8“ – 1.3/8“ respectively
and steel pipes with a diameter of 1/8“ – 1.1/4“
ROFROST TURBO II: Copper pipes with a diameter of 10 – 60 mm or 3/8“ – 2.1/8“ respectively
and steel pipes with a diameter of 1/8“ – 2“.
Other applications are not permissible.