To turn on/off the gas boiler
1
Push the button.
Result:
The green LED above the button will light up when the
boiler is ON.
When the gas boiler is OFF, is displayed on the service display to
indicate that the power is ON. In this mode, the pressure in the
space heating installation will also be displayed on the main display
(bar).
Domestic hot water comfort function
This function can be operated with the domestic hot water comfort
key (
). The following functions are available:
▪
On: The LED lights up. The domestic hot water comfort function
is switched on. The heat exchanger will be kept on temperature to
assure instant delivery of hot water. At first start-up, the boiler is
factory set to Eco. At next start-ups the boiler will remember the
previous setting.
▪
Eco: The LED lights up. The domestic hot water comfort function
is self-learning. The appliance will learn to adapt to the pattern of
use of hot tap water. For example: the temperature of the heat
exchanger will NOT be maintained during the night or in case of
long absence.
▪
Off: Both LED's are OFF. The temperature of the heat exchanger
is NOT maintained. For example: It will take a while to deliver hot
water to the hot water taps. If there is no need for hot tap water or
there is no need for immediate hot water delivery, the domestic
hot water comfort function can be turned OFF.
To reset the gas boiler
Resetting is only possible when an error occurs.
Prerequisite:
Flashing LED above the button and an error code
on the main display.
Prerequisite:
Check the meaning of the error code (see
"Error
codes of the gas boiler" on page 30
) and resolve the cause.
1
Press to restart the gas boiler.
Maximum space heating supply temperature
See the user reference guide of the indoor unit for more details.
Domestic hot water temperature
See the user reference guide of the indoor unit for more details.
To set the parameters via the service code
The gas boiler is factory set in accordance with the default settings.
Take into account the remarks in the table below when changing the
parameters.
1
Press simultaneously on
and until appears on the main
and the service display.
2
Use the and buttons to set (service code) on the main
display.
3
Press the
button to set the parameter on the service display.
4
Use the and buttons to set the parameter to the desired
value on the service display.
5
When all settings are done, press until appears on the
service display.
Result:
The gas boiler has now been reprogrammed.
INFORMATION
▪
Press the button to exit the menu without storing the
parameter changes.
▪
Press the
button to load the default settings of the
gas boiler.