7 Installation
Installation and operation manual
17
RHYKOMB33AA
ROTEX HPU hybrid gas boiler module
4P353068-1 – 2013.07
7.7.5
Applicable materials
Only use the materials specified in the following table.
Device category
Material
Supplier per country
D
B
I
C
13
All materials
▪
Rotex
▪
3rd party
(b)
Rotex
▪
Rotex
▪
3rd party
(b)
C
33
C
53
C
43
▪
All materials
▪
CLV systems
(a)
(a)
(a)
C
83
▪
Inlet grille
▪
Main pipe
▪
Other parts
(a)
(a)
(a)
(a)
Contact your local Rotex dealer for advise on the applicable materials and the installation requirements.
(b)
All parts purchased from an external supplier MUST comply with EN14471.
7.7.6
Flue pipe position
Especially for UK:
Only use flue products approved by the boiler manufacturer, which can be
bought from the supplier of your boiler.
Refer to the field supplied accessories for all available accessories.
P
S
C
B
A
M
R
D
J
Q
G
A
Q
Q
N
P
T2
T2
T2
T1
H
T
I
K
L
F
F
N
E
Minimum
Terminal
position
distance
A
Directly below an open able window or
300 mm
other opening (e.g. air brick)
B
Below gutters, soil pipes or drain pipes
75 mm
C
Below eaves
200 mm
D
Below balconies or car front roofs
200 mm
E
From vertical drain pipes and soile pipe
150 mm
F
From internal or external corners
300 mm
G
Above ground, roof or balcony level
300 mm
H
From a surface facing a terminal
600 mm
I
From a terminal discharging towards
1200 mm
another
terminal
J
From an opening in a car port (e.g. door,
1200 mm
window) into a dwelling
K
Vertically from a terminal on the same wall
1500 mm
L
Horizontally from a terminal on the same wall 300 mm
M
Above an opening, air brick, opening
300 mm
windows,
etc.
N
Horizontally to an opening, air brick,
300 mm
opening windows, etc.
P
Above roof level (to base of terminal)
300 mm
Q
From adjacent wall to flue
300 mm
R
From an adjacent opening window
1000 mm
S
From another roof terminal
600 mm
-
From an external boundary. Note: If the
600 mm
terminal is facing a boundary, it is
recommended that an anti-plume kit be fitted.
T
Terminals adjacent to windows or openings
on pitched and flat roofs:
The flue should NOT penetrate this area.
T1
2000
mm
T2
600
mm
NOTICE
The boiler manufacturer cannot be held responsible for
atmospheric conditions when siting flue terminals.
CAUTION
Once the flue system has been installed and the appliance
commissioned, the installer should observe the plume
direction. Particular attention should be drawn to plume
vapour re-entering the boiler via the air intake. If this occurs,
it is highly possible the flue is fitted with a negative pressure
area and therefore a plume management kit MUST be fitted.