For a dual pipe connection, all defined lengths assume a diameter of
80 mm. In case of smaller or larger pipe diameters, the permissible
pipe length is respectively smaller or larger. In case of smaller
diameter, the following applies:
▪
Ø70: 0.59 × the permissible pipe length for Ø80
▪
Ø60: 0.32 × the permissible pipe length for Ø80
▪
Ø50: 0.15 × the permissible pipe length for Ø80
Contact the manufacturer to check the calculations for the resistance
of the air supply and combustion gas flue pipe and the wall
temperature at the end of the combustion gas flue pipe.
L6
L4
L3
L1
L2
L5
Sample calculation for dual pipe application
Pipe
Pipe length
Total pipe length
Flue pipe
(L1+L2+L3+2) × 2 m 13 m
Air supply
(L4+L5+L6+2) × 2 m 12 m
Total piping length = sum of the straight pipe l sum of the
equivalent pipe length of bends/elbows.
7.7.4
Appliance categories and pipe lengths
Following installation methods are supported by the manufacturer.
1
L1
L1
L1
L2
L2
L1
L2
3
4
2
L1
L2
6
5
C
33
C
33
6
5
C
43
C
13
C
43
C
83
C
83
C
53
L2
C
13
(1)
C
33
(2)
C
13
(1)
C
33
(2)
60/100
60/100
Twin-80
Twin-80
L1 (m)
L1 (m)
L1 (m)
L1 (m)
9.7
10
21.3
21.3
C
13
(1)
C
33
(2)
C
33
(4)
C
53
(3)
80/125
80/125
60/100
80
60/100
60
L1 (m)
L1 (m)
L1 (m)
L2 (m)
L1 (m)
L2 (m)
29
29
9
1
6
1
1
30
1
10