19. Preset Templates
The following presets are designed to be
starting points for a variety of common types
of contours. Their Global parameters have
been set up, conditional jumps, if used, have
been programmed, and stand-in values have
been provided for Time, Level, and Transition
Shape. We’d expect you to change those
parameters to suit your specific needs.
To use the templates, load the one you
want and then
immediately resave it to a
different location
and rename it as desired.
That way the original template is still available
unchanged for when you want to use it
again.
In most cases, you can check out the
templates with the basic patch described
below. If a different patch is required for a
particular template, it will be described in that
preset’s listing.
The basic patch
>
Patch the
+Output
to the CV in of a
VCO and/or VCF and/or VCA or other
processor. (It’s easiest to clearly hear
what’s happening with a preset by
listening to its effect on a VCO.)
>
Patch the
Trigger 1
output to the gate
input of an envelope or other triggered CV
source.
>
Patch the output from a gate or trigger
source into the
Gate/Trig
input.
>
Patch a CV source into the
Time Scale CV
input (preferably through an attenuator).
300 One Shot
This is a simple 8-segment one shot contour.
A rising edge at the Gate/Trig input (or press
of the Manual Gate button) starts it and resets
it to the beginning if it’s already running. It
automatically stops at the end of Segment 8.
Trigger 1 fires at the beginning of Segment 1
Trigger 2 fires at the beginning of every
segment.
Customize the template by selecting new
levels, times, shapes and time scale.
301 1 Shot Pass
This is the same contour as 301 above,
except Segment 3 has been set to CV 1
Passthrough and Segment 6 has been set to
CV 2 Passthrough. Patch external signals into
CV 1 and CV 2 inputs and they will be passed
through to the output during their respective
segments.
Trigger 1 fires at the beginning of Segment 1
Trigger 2 fires at the beginning of every
segment.
Customize the template by selecting new
levels, times, shapes and time scale.
302 Cond LFO
This template provides a basic sine LFO in the
first four segments. As long as CV 3 is below
2V, Segment 4 will continuously loop back to
Segment 1.
When CV 3 is greater than 2V at the end of
Segment 4, the contour will continue on
to the remainder of the segments and then
loop back to Segment 1. If CV 3 falls back
below 2V, the contour will return to looping
segments 1-4.
In Play Mode, the encoder sets the tempo of
the LFO.