![Rossum Control Forge Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/rossum/control-forge/control-forge_operation-manual_1489496010.webp)
10
|
Additionally, the CVs at these inputs are
passed directly through to the output during
any segment whose shape is
CV 1
or
CV 2
Passthrough
.
Time Scale CV
This input accepts CVs in the range of -5V
to +5V. Voltages outside of that range are
clipped to the appropriate limit.
The value of the CV modifies the
Time
values
of all of a preset’s segments such that a 1 volt
change increases the Time Scale Rate value
by a factor of 2. Therefore, overall range of
modification is from 1/32 of the set time to
32 times the set time.
In Play Mode, the
Encoder
also controls
time scale. Its value is multiplied by the Time
Scale CV to provide the final time scale
modification value.
Sequencer Dec, Inc, and Reset
Depending on the Preset Sequencer state,
rising edges at these inputs control the
loading of a sequence’s programmed presets.
See
Chapter 17
for details.
Outputs
+ Output
Outputs the CV contour in the
range of -5V to +5V. Accuracy is
approxi/-1mV.
- Output
Outputs a precisely inverted
version of the CV contour in the
range of -5V to +5V.
Trigger 1
Outputs a +10V trigger or gate
pulse whenever the condition
set in the
Assign Trigger 1
menu
is met or the
Conditional Value/
Trigger 1
button is pressed while
in Play Mode.
Trigger 2
Outputs a +10V trigger or gate
pulse whenever the condition set in the
Assign Trigger 2
menu is met or the
Assign
Triggers/Trigger 2
button is pressed while in
Play Mode.
Controls
Data/Time Scale Encoder
The Encoder is used
in
Program Mode
to set the values of
parameters selected
via the parameter
push buttons or
knobs.
The Encoder
includes an integrated pushbutton that is
typically used to enter the currently selected
value (see individual parameters for details).
In
Play Mode,
the encoder serves as a real
time control over Time Scale. The time scale
range is between X 0.031 and X 32X in 80
approximately logarithmic steps. Pressing
and holding the encoder switch and turning
it quantizes the Time Scale values to factors
of 2.
Global/Pause/Utilities Button
In
Play Mode,
if Control Forge is running,
quickly pressing this button causes playback
to pause. Pressing it again causes playback to
resume from the paused location. Pressing
and holding this button brings up the
Utilities
Menu
described in
Chapter 18.
In
Program Mode,
quickly pressing this button
brings up the
Preset Globals
menu described
in
Chapter 8.
If Control Forge is running,
pressing and holding this button causes
pausing and resuming playback.
NOTE:
Yes, we realize the short press/long press
functionality is reversed between Play and
Program Modes. While we prefer things
to be consistent, after long discussion we
came to the conclusion that it was more
important that the things you were most most
likely to do in each mode were accessed with a
short press.
Manual Gate Button
Содержание Control Forge
Страница 70: ...70 ...