![Ross NK RCP-NKM Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/ross/nk-rcp-nkm/nk-rcp-nkm_user-manual_1488797033.webp)
RCP-NKM User Guide (v3.0)
Setting Up the RCP-NKM • 4–15
To assign a protect key
1.
Open the RCP-NKM editor (see “
2.
On the simulated RCP-NKM, select the key that you want to use for the protect key.
3.
In the pop-up dialog:
a.
Select
Function
as the key type.
b.
Select
Protect
as the key value.
The simulated RCP-NKM in DashBoard shows
PROT
on the selected key.
4.
Select the
Configuration
tab.
5.
Scroll to the
Configuration
frame.
6.
Select the mode of protection that you want for the protect key. Use the information in
as a guide..
7.
Send the current document to the device by clicking
Send Configuration
located on the lower Device
Configuration window (see “
Sending a Document to a Device
Assigning a TAKE Key
If you want to pre-load a switch sequence, but delay the switch, assign a
TAKE
key on the menu. If a
TAKE
key is
assigned, then all switches on that menu are activated by pressing the
TAKE
key instead of the
source/crosspoint/macro key. You should assign a
TAKE
key on each menu that requires this switching type.
To assign a TAKE key
1.
Open the RCP-NKM editor (see “
2.
On the simulated RCP-NKM, select the key that you want to use for the
TAKE
key.
3.
In the pop-up dialog:
a.
Select
Function
as the key type.
b.
Select
Take
.
The simulated RCP-NKM in DashBoard shows
TAKE
on the selected key.
4.
Send the current document to the device by clicking
Send Configuration
located on the lower Device
Configuration window (see “
Sending a Document to a Device
Assigning a CHOP Key
If you want to toggle two different sources to the same destination, assign a
CHOP
key to the RCP-NKM. For
example, the destination may be the monitor that you are viewing, and the sources may be feeds from two different
camera locations. When you use the
CHOP
key, the toggle rate can be slow or fast (see “
Table 4.5 Protection Descriptions
Protect Mode
Description
Block Other Panels
The protected destination and level(s)
cannot
be switched to another source
by other remote control panels.
The protected destination and level(s)
can
be switched to another source on
the current remote control panel.
Block All Panels
The protected destination and level(s)
cannot
be switched to another source
by the current remote control panel or other remote control panels.
Содержание NK RCP-NKM
Страница 1: ...RCP NKM User Guide...
Страница 6: ......
Страница 10: ...1 2 Introduction RCP NKM User Guide v3 0...
Страница 14: ...2 4 RCP NKM Overview RCP NKM User Guide v3 0...
Страница 54: ...6 2 Troubleshooting RCP NKM User Guide v3 0...
Страница 56: ...7 2 Hexadecimal to Router Level Conversion RCP NKM User Guide v3 0...