Ross NK RCP-NKM Скачать руководство пользователя страница 25

RCP-NKM User Guide (v3.0)

Setting Up the RCP-NKM • 4–7

12.

Send the current document to the device by clicking 

Send Configuration

 located on the lower Device 

Configuration window.

Notes

Keep the following in mind:

• If you click and drag across the level mask, you can rapidly select or de-select router levels.
• The breakaway defined in the first row of the 

Breakaway

 table is the default breakaway.

• You can combine more than one router level in the same breakaway. Give the breakaway a meaningful name that 

covers the router levels that you want to use. Limit the name to 8 characters.

• A breakaway warning is caused by no response from the routing switcher system on one or more router levels or 

a difference in status of any level in the currently selected breakaway when compared with the first level in the 
breakaway

• The default breakaway and any custom breakaways may now be assigned to keys on the RCP-NKM 

For More Information on...

• sending the current document to the device, see “

Sending a Document to a Device

” on page 4–23.

• assigning breakaways to keys, see “

Assigning a Breakaway to a Key

” on page 4–12.

Resetting a Custom Breakaway to the Default Breakaway Automatically After a Switch

The default breakaway is defined in the first row of the 

Breakaways

 table in the 

Breakaways

 frame. Typically, this 

breakaway is tied, and switches all router levels together. If you want only certain router levels to switch, as defined 
in a custom breakaway, you select that breakaway on the RCP-NKM, then make the switch. The RCP-NKM 
continues to use that breakaway (as indicated by the key being illuminated) for all further switches until another 
custom breakaway, or the default breakaway is selected. If you want the RCP-NKM to reset to the default 
breakaway immediately after a custom breakaway is used during a switch, then you should set the RCP-NKM to 
reset the breakaway.

To enable the resetting of the breakaway to the default breakaway automatically after a switch

1.

Open the RCP-NKM editor (see “

Opening the RCP-NKM Editor

” on page 4–1).

2.

Select the 

Configuration

 tab.

3.

Scroll to the 

Configuration

 frame.

4.

Select the 

Breakaway Reset

 check box.

5.

Send the current document to the device by clicking 

Send Configuration

 located on the lower Device 

Configuration window (see “

Sending a Document to a Device

” on page 4–23).

Setting Up Menus

Menus may be used to group certain functionality within the RCP-NKM together. You can store up to 250 menu 
pages in the RCP-NKM. You can also set up what happens after an activity has been performed in a particular 
menu, that is, you can define the fallback. Each menu page provides a new set of 40 keys that you may assign with 
new functions.

For example, if you set up a menu containing all the breakaways, another menu containing all the destinations and 
another menu containing all the sources, you can set up the menus so that once you have selected a breakaway, the 
menu containing all the destinations is shown so that you can select a particular destination device. Following this, 
the menu containing all the sources is shown so that you can select a particular source device. Another use may be 
to define all the different classes of inputs, then assign these to menu links on the top row of keys on the RCP-NKM 
for each menu page. This process can then be repeated for outputs. When this configuration is used, the top row of 
keys always stays the same for each menu; it is the function of the bottom row of keys that changes from menu to 
menu.

Содержание NK RCP-NKM

Страница 1: ...RCP NKM User Guide...

Страница 2: ...eople that make things happen At Ross our employees are a special group Our employees truly care about doing a great job and delivering a high quality customer experience every day This code of ethics...

Страница 3: ...ment of Compliance This product has been determined to be compliant with the applicable standards regulations and directives for the countries where the product is marketed Compliance documentation su...

Страница 4: ...bility and fitness for a particular purpose are expressly limited to the duration of this warranty This warranty is TRANSFERABLE to subsequent owners subject to Ross notification of change of ownershi...

Страница 5: ...O Box 880 Ogdensburg New York USA 13669 0880 General Business Office 1 613 652 4886 Fax 1 613 652 4425 Technical Support 1 613 652 4886 After Hours Emergency 1 613 349 0006 E mail Technical Support t...

Страница 6: ......

Страница 7: ...nections for Control by an RCP NKM 4 5 Setting Up Breakaways 4 6 Setting Up Menus 4 7 Assigning Functions to Keys on the RCP NKM 4 8 Unassigning a Key 4 18 Locking an RCP NKM 4 18 Setting Up Cutbus Op...

Страница 8: ...a Machine Control Port 5 7 De Assigning Resources 5 8 Operating Linked Remote Control Panels 5 8 Resetting Devices 5 9 Viewing Status and Alarms 5 9 Adjusting the Contrast for the LCD 5 10 Troublesho...

Страница 9: ...casting Please read this thoroughly and retain it for future reference The RCP NKM provides flexible connectivity of additional remote control panels and multi page menu programming Overview of this U...

Страница 10: ...1 2 Introduction RCP NKM User Guide v3 0...

Страница 11: ...e control panel At each menu the function of particular keys may change depending on the assignment These parameters can be saved in a configuration document and sent to an RCP NKM at any time using D...

Страница 12: ...oard Audio out Audio out Server 1 Server 2 VTR 1 VTR 2 Audio in Server 3 Audio in Video in Audio in Monitor Appropriate NK Series power supply Input 1 Input 2 Input 7 Output 15 Output 20 Output 8 Audi...

Страница 13: ...es the request sets the crosspoint then sends a response to the RCP NKM Data Storage The RCP NKM stores information on the menu destination level breakaway and machine control status The routing switc...

Страница 14: ...2 4 RCP NKM Overview RCP NKM User Guide v3 0...

Страница 15: ...cal inputs and outputs and have appropriate NK Series power supplies All NK Series equipment connected in the routing switcher system have firmware v2 00 or later For information on updating the firmw...

Страница 16: ...V 2 A power supply provided to the POWER connector on the rear panels of the RCP NKM 4 Connect the cable from the power supply to a suitable AC mains supply The RCP NKM is designed for installation in...

Страница 17: ...ration document to the RCP NKM you must connect an NK IPS to the RCP NKM Once DashBoard locates the NK IPS the attached RCP NKM is visible and can have configuration documents sent to it Most systems...

Страница 18: ...ntact Ross Video Technical Support Using DashBoard to Check the Firmware Version To check the firmware version of any device using DashBoard 1 Launch DashBoard and connect to the NK IPS 2 In the Devic...

Страница 19: ...e routing switcher system have firmware v2 00 or later To open the RCP NKM editor 1 Launch DashBoard and connect to the NK IPS 2 In the Device Tree of DashBoard expand the NK IPS or NK NET node to dis...

Страница 20: ...escription Serial Num read only This parameter is read only The serial number of the device This is set in the factory It is unique to the device If you are working on a file that is stored under File...

Страница 21: ...editor in the DashBoard Name user definable The name for the device The default name for the RCP NKM is RCP NKM This parameter may be changed to any name that uniquely identifies the device for examp...

Страница 22: ...can link the remote control panels together so that they operate as one larger remote control panel For more information see Operating Linked Remote Control Panels on page 5 8 You may link RCP NKM and...

Страница 23: ...To change the number of possible inputs and outputs 1 Open the RCP NKM editor see Opening the RCP NKM Editor on page 4 1 2 Do one of the following To change the number of inputs select the Input Assig...

Страница 24: ...ssign this to a key on the RCP NKM see Assigning Functions to Keys on the RCP NKM on page 4 8 If you select a breakaway that includes a level for which there is no routing switcher assigned a breakawa...

Страница 25: ...m breakaway or the default breakaway is selected If you want the RCP NKM to reset to the default breakaway immediately after a custom breakaway is used during a switch then you should set the RCP NKM...

Страница 26: ...y Assigning Functions to Keys on the RCP NKM The RCP NKM is programmed in the factory with default key assignments see Default Configuration on page 4 3 If this default key assignment is not suitable...

Страница 27: ...he function of any crosspoint key on a menu is changed when a TAKE key is assigned to the menu see Take Level A specific router level assigned to a key Pressing a level key selects that router level M...

Страница 28: ...provides a convenient method for disconnecting machine control ports For more information see Setting Up Machine Control on page 4 19 A single key that allows you to free up resources when they are no...

Страница 29: ...t1 and Shift2 When shift keys are assigned to the RCP NKM the physical output assigned to that key on that shift page is used for the switch For more information see Assigning a Shift to a Key on page...

Страница 30: ...4 6 To assign a breakaway to a key 1 Open the RCP NKM editor see Opening the RCP NKM Editor on page 4 1 2 On the simulated RCP NKM select the key that you want to use for the breakaway 3 In the pop up...

Страница 31: ...ey must be assigned on the RCP NKM before you can use it to record the macro To record a macro using the panel 1 On the RCP NKM hold the Macro n key until the LCD shows MACRO RECORD and the key illumi...

Страница 32: ...ollowing a Double click the Input box b Enter a source for the event c Press Enter 8 In the Level Mask column select the level mask or masks for the device affected by the macro Each function can occu...

Страница 33: ...KE key 1 Open the RCP NKM editor see Opening the RCP NKM Editor on page 4 1 2 On the simulated RCP NKM select the key that you want to use for the TAKE key 3 In the pop up dialog a Select Function as...

Страница 34: ...y for destinations To assign a shift to a key 1 Open the RCP NKM editor see Opening the RCP NKM Editor on page 4 1 2 On the simulated RCP NKM select the key that you want to use for the shift 3 In the...

Страница 35: ...ocated below the simulated RCP NKM 5 Assign functions to the keys in this menu see Assigning Functions to Keys on the RCP NKM on page 4 8 For example if this menu is for the purpose of selecting a des...

Страница 36: ...only be unlocked via DashBoard To lock the RCP NKM 1 Open the RCP NKM editor see Opening the RCP NKM Editor on page 4 1 2 Select the Configuration tab 3 Scroll to the Configuration frame 4 Select the...

Страница 37: ...use the up and down arrows in the Cutbus Dest 2 field to assign the new destination 8 Send the current document to the device by clicking Send Configuration located on the lower Device Configuration...

Страница 38: ...With virtual routing physical inputs and outputs are mapped to virtual sources and destinations For example a virtual source may switch input 15 on level 1 and input 27 on level 2 The RCP NKM must ha...

Страница 39: ...hting for the keys on the RCP NKM so that you can distinguish between whether or not they are active You can set the minimum level of backlighting so that it can be read in a darkened room when it is...

Страница 40: ...e Load Factory Defaults check box 5 Send the current document to the device by clicking Send Configuration located on the lower Device Configuration window see Sending a Document to a Device on page 4...

Страница 41: ...information that has been changed are automatically selected for sending to the device 2 Select the pages that you want to send to the device Use the information Table 4 9 as a guide 3 Select the dev...

Страница 42: ...power from the RCP NKM 6 Remove the facing panel from the RCP NKM by gently levering it away from the frame 7 Insert the corresponding labels into the keys so that they display correctly 8 Position th...

Страница 43: ...tion the name of this destination is shown in the bottom line of the screen and the name of the last selected source for that destination is shown in the top line of the screen and the corresponding k...

Страница 44: ...ave selected a custom breakaway and separate level keys are assigned to the RCP NKM the level keys corresponding to the levels in the breakaway also illuminate When a breakaway is selected the status...

Страница 45: ...a look up table for reading the levels from the hexadecimal characters To view the levels defined in a breakaway 1 Select the breakaway 2 Hold the breakaway step key An 8 character expression appears...

Страница 46: ...sspoint key flashes with the TAKE key 2 If a TAKE key is assigned to the menu press TAKE 3 If you want to protect the switch press the protect key if it has been assigned see Protecting a Destination...

Страница 47: ...thers The protect function ensures that the selected destination can only receive the selected source across the selected levels Once protected the selected levels on a destination cannot be switched...

Страница 48: ...on frame 4 If you want to clear all protects held by the RCP NKM select the Clear Protect s check box 5 Send the current document see Sending a Document to a Device on page 4 23 Protects may be held b...

Страница 49: ...s the menu assigned to it A brief message is shown on the screen with the name of the menu For example 2 Press the key that you want to use in that menu If the menu has been set up to fall back to ano...

Страница 50: ...s combine to form one big remote control panel Up to 255 remote control panels may be linked together If you want to define all the crosspoints that you need without using menus and pages you need as...

Страница 51: ...urn to a known operating state and configuration you can send the default document to the RCP NKM see Sending a Document to a Device on page 4 23 reset the device reload the factory defaults If the RC...

Страница 52: ...Adjusting the Contrast for the LCD To Adjust the contrast 1 Insert a Phillips head screwdriver into the Display Contrast trimpot on the rear panel of the RCP NKM 2 Adjust the trimpot until the contra...

Страница 53: ...Setting Up Virtual Routing and Resource Management on page 4 20 I get a PROT BRKWY ERR when the PROTECT button is pressed At least one crosspoint across the router levels defined in the current break...

Страница 54: ...6 2 Troubleshooting RCP NKM User Guide v3 0...

Страница 55: ...0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 0 0 0...

Страница 56: ...7 2 Hexadecimal to Router Level Conversion RCP NKM User Guide v3 0...

Отзывы: