![Ross 4500DR-204-03 Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/ross/4500dr-204-03/4500dr-204-03_user-manual_1488930037.webp)
ACO-4500 User Guide (v3.0)
Front Panel Menu System • 37
Auto
When set to
Auto
, fault detection is enabled, the outputs will automatically default to the Primary inputs, and, when
applicable, automatic switching of inputs occurs when a fault is encountered:
When a Primary fault is repaired, the output will automatically switch back to the Primary input when the signal is
re-connected (provided the signal conforms to that channel's configuration).
Manual
When set to
Manual
, fault detection is “disabled”, and the user is able to manually switch the output to be either the
Primary or Backup input, irrespective of any existing faults.
Output
This menu line displays which of the inputs is currently switched to the output. The options for the field are:
Primary, Backup. The user can only switch the output to Backup when the “Operational Mode” is set for “Manual”.
Other Menus
The Signal Strength Menu, Channel Setup Menu, and System Setup Menu provide access to further menus or
features, all of which are detailed in the following pages.
Signal Strength Menu
provides an example of the Signal Strength Menu.
Figure 7.5 Signal Strength Menu Example
The Signal Strength Menu provides a graphical view of the amplitude of all signals connected to the ACO-4500.
Table 7.1 Fault Actions
Fault on
Switch
No fault
Primary
Primary
Backup
Backup
Primary
Primary & Backup
Backup
Channel # = POK X BOK X
Содержание 4500DR-204-03
Страница 1: ...ACO 4500 User Guide ...
Страница 6: ......
Страница 10: ...iv Contents ACO 4500 User Guide v3 0 ...
Страница 34: ...34 Getting Started ACO 4500 User Guide v3 0 ...
Страница 54: ...54 Troubleshooting ACO 4500 User Guide v3 0 ...
Страница 62: ...62 Connector Pinouts ACO 4500 User Guide v3 0 ...
Страница 68: ...68 Service Information ACO 4500 User Guide v3 0 ...
Страница 70: ...70 Glossary ACO 4500 User Guide v3 0 ...