1. INSTRUCTIONS FOR THE INSTALLER
2. ELECTRICAL CONNECTION
(FOR U.K. ONLY)
INSTALLING A DOMESTIC APPLIANCE CAN BE A COMPLICATED OPERATION WHICH IF NOT CARRIED OUT CORRECTLY, CAN SERIOUSLY
AFFECT CONSUMER SAFETY. IT IS FOR THIS REASON THAT THE TASK SHOULD BE UNDERTAKEN BY A PROFESSIONALLY QUALIFIED
PERSON WHO WILL CARRY IT OUT IN ACCORDANCE WITH THE TECHNICAL REGULATIONS IN FORCE. IN THE EVENT THAT THIS ADVICE IS
IGNORED AND THE INSTALLATION IS CARRIED OUT BY AN UNQUALIFIED PERSON, THE MANUFACTURER DECLINES ALL RESPONSIBILITY
FOR ANY TECHNICAL FAILURE OF THE PRODUCT WHETHER OR NOT IT RESULTS IN DAMAGE TO GOODS OR INJURY TO INDIVIDUALS.
1.1 BUILDING IN
1.2. SUITABLE LOCATION
2.1. ELECTRICAL CONNECTION
LIVE
EARTH
NEUTRAL
L
N
Power Cable
Brown Wire
Green/Yellow Wire
Blue Wire
Mains Supply
2.2. GAS CONNECTION
These instructions are for qualified personnel, installation of
equipment must be in line with the relevant national standard.
(For
U.K. only: by law the gas installation\commissioning must be
carried out by a "Gas Safe" installer)
All work must be carried out with the electricity supply disconnected.
The rating plate on the hob shows the type of gas with which it is
designed to be used. Connection to the mains gas supply or gas
cylinder should be carried out after having checked that it is regulated
for the type of gas with which it will be supplied. If it is not correctly
regulated see the instructions in the following paragraphs to change
gas setting
For liquid gas (cylinder gas) use pressure regulators which comply
with the relevant national standards.
Use only pipes,washers and sealing washers which comply with the
relevant national standards.
To prevent any potential damage to the hob please carry out the
installation following this sequence (picture 6):
1)As illustrated, assemble parts in sequence:
A: 1/2 Male Adaptor Cylindirical B: 1/2 Seal
C: 1/2 Female Gas Adaptor Conical-Cylindirical or
Cylindirical-Cylindirical
2)Tighten the joints with the spanner, remembering to twist the
pipes into position.
3)Attach fitting C to mains gas supply using rigid copper pipe or
flexible steel pipe.
For some models a conic link is furnished to outfit for the installation in
the countries where this type of link is obligatory; in picture 8 it is
pointed out how to recognize the different types of links (CY =
cylindrical, CO = conic). In every case the cylindrical part of the link
has to be connected to the hob.
When connecting the hob to the gas supply via use of flexible hoses
please ensure that the maximum distance covered by the hose does
not exceed 2 metres.
The flexible tube shall be fitted in such a way that it cannot come into
contact with a moveable part of the housing unit (e.g. a drawer) and
does not pass through any space where it may become crushed/
kinked or damaged in any way.
Check the data on the rating plate, located on the outside of the unit, to
ensure that the supply and input voltage are suitable.
Before connection, check the earthing system.
By Law, this appliance must be earthed. If this regulation is not
complied with, the Manufacturer will not be responsible for any
damage caused to persons or property. If a plug is not already
attached, fit a plug appropriate to the load indicated on the rating plate.
The earth wire is coloured yellow/green. The plug should always be
accessible.
Where the Hob is connected direct to the electricity supply, a circuit
breaker must be fitted.
If the supply cord is damaged, it must be replaced by the manufacturer
its service agent or similary qualified persons in order to avoid a
hazard.
WARNING: If the surface is cracked, switch off the appliance to avoid
the possibility of electric shock.
The earth wire ( green and yellow coloured ) must be at least 10 mm
longer than the live and neutral wires.
The means for disconnection must be incorporated in the fixed wiring
in accordance with the wiring rules.
If an appliance is not fitted with a supply cord and a plug, or with other
means for disconnection from the supply mains having a contact
separation in all poles that provide full disconnection under
overvoltage category III conditions, the instructions shall state that
means for disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules.
Warning - this appliance must be earthed
This appliance is designed for domestic use only. Connection to the main
supply must be made by a competant electrician, ensuring that all current
regulations concerning such installations are observed.
The appliance must only be connected to a suitably rated spur point, a 3
pin 13 amp plug/socket is not suitable. A double pole switch must be
provided and the circuit must have appropriate fuse protection. Further
details of the power requirement of the individual product will be found in
the users’ instruction and on the appliance rating plate. In the case of built-
in product you are advised, should you wish to use a longer cable than the
one supplied, that a suitably rated heat resistant type must be used.
The wiring must be connected to the mains supply as follows:
CONNECT
TO SPUR TERMINAL
Green & Yellow Wire
Earth Connection
Blue Wire
Neutral Connection
Brown Wire
Live Connection
Note:
We do not advocate the use of earth leakage devices with electric
cooking appliances installed to spur points because of the «nuisance
tripping» which may occur. You are again reminded that the appliance
must be correctly earthed, the manufacturer declines any responsibility for
any event occurring as a result of incorrect electrical installation.
This appliance must be installed in accordance with the regulations in
force and only used in a well ventilated space. Read the instructions before
installing or using this appliance.
A gas-powered cooking appliance produces heat and humidity in the area
in which it is installed. For this reason you should ensure good ventilation
either by keeping all natural air passages open or by installing an extractor
hood with an exhaust flue. Intensive and prolonged use of the appliance
may require extra ventilation, such as the opening of a window or an
increase in speed of the electric fan, if you have one.
Prior to installation, ensure that the local distribution conditions (nature of
the gas and gas pressure) and the adjustment of the appliance are
compatible;
The adjustment conditions for this appliance are stated on the label (or
data plate);
This appliance is not connected to a combustion products evacuation
device. It shall be installed and connected in accordance with current
installation regulations. Particular attention shall be given to the relevant
requirements regarding ventilation.
If a hood can not be installed, an electric fan should be fitted to an outside
wall or window to ensure that there is adequate ventilation.
The electric fan should be able to carry out a complete change of air in the
kitchen 3-5 times every hour. The installer should follow the relevant
national standards.
The hob may be installed in any worktop which is heat resistant to a
temperature of 100°C, and has a thickness of 25-45 mm. The dimensions
of the insert to be cut out of the worktop are in shown in
Figure 2.
If the Hob is fitted next to a cabinet on either side, the distance between the
Hob and the cabinet must be at least 15 cm
(see Figure 4)
; while the
distance between the hob and the rear wall must be at least 5,5 cm.
The distance between the hob and any other unit or appliance above it
(e.g. An extractor hood) must be no less than 70 cm
(Figure 4)
.
When there is an accessible space between the built-in hob and the cavity
below, a dividing wall made of insulating material should be inserted (wood
or a similar material)
(Figure 3).
Important - The diagram in figure 1 shows how the sealant should be
applied.
The Hob unit is fitted by attaching the Fixing Clamps supplied, using the
holes at the base of the unit.
If a hob of 60 cm is fitted above an oven which is not equipped with fan
cooling system it is recommended that openings are created within the
built in furniture to ensure correct air circulation.
The size of these openings must be at least 300 cm2 and placed as shown
in
Figure 5.
CAUTION: In order to avoid a hazard due to inadvertent resetting of the
thermal cutout, this appliance must not be supplied through an external
switching device, such as a timer, or connected to a circuit that is regularly
switched on and off by the utility.
These instructions are only valid if the country symbol appears on the
appliance. If the symbol does not appear on the appliance, it is necessary
to refer to the technical instructions which will provide the necessary
instructions concerning modification of the appliance to the conditions of
use of the country.
This appliance is not intended to be operated by means of an external
timer or separate remote-control system.