background image

User Manual 

 

RPC-2.92 Calibration Kit 

02CK001-150 and 02CK010-150

 

02CK001-150 

 

 

Rosenberger Hochfrequenztechnik GmbH & Co. KG  
P.O.Box 1260       D-84526 Tittmoning       Germany 
www.rosenberger.com

 

Tel.    : +49 8684 18-0  
 
Email : [email protected]

 

Page 

 

10 / 17

 

 

D

ie

s

e

s

 D

o

k

u

m

e

n

is

u

rh

e

b

e

rr

e

c

h

tl

ic

h

 g

e

s

c

h

ü

tz

 T

h

is

 d

o

c

u

m

e

n

is

 p

ro

te

c

te

d

 b

y

 c

o

p

y

ri

g

h

 R

o

s

e

n

b

e

rg

e

H

o

c

h

fr

e

q

u

e

n

z

te

c

h

n

ik

 G

m

b

H

 &

 C

o

K

G

 

5. Calibration Kit Service 

5.1 Calibration interval 

 
Rosenberger suggests a calibration interval of 12 months. Depending on the frequency of use, the 
wear and the actual requirements a different calibration interval might be suitable. This lies in the 
responsibility of the user.  
 

5.2 Spare parts 

 
Each  part  of  this  kit  can  be  ordered  separately  as  spare  part  with  reference  to  the  part  number 
shown  in  Table  1-1  /  Table  1-2  and  the  quantity  desired.  Telephone  or  send  your  order  to  your 
local Rosenberger sales office. 
 

5.3 Where to send a Kit for Re-Calibration / Repair 

 
In case of re-calibration or repair contact your local Rosenberger sales office.  
 

5.4 Extent of Rosenberger Re-Calibration Services 

 
Every calibration kit sent for re-calibration or repair the following services are performed 

  Cleaning of connector interfaces 

  Optical check of connector mating planes, contact pins and contact fingers 

  Check of connector gauge for impermissible protrusion and significant recession 

  Electrical measurement of all calibration standards 

  Measurement of torque wrench torque 

  Measurement of gauges 

  Issuing of calibration certificates including measurement values and uncertainties 

  Individual  optimizing  of capacitive  coefficients  C0  to  C3 for  all  Open  calibration  standards  and 

short  inductance  coefficients  L0  to  L3  for  all  Short  calibration  standards  for  best  fitted  model 
based standard definitions. 

 
In case of any defect or abnormality a cost estimation will be issued before continuing repair work. 
 
If a calibration standard has to be replaced or modified, the incoming status is additionally reported 
in  the  calibration  certificate.  This  service  is  excluded  when  this  measurement  may  damage  the 
Rosenberger measurement setup. 
 
 
 

 

 

 

Содержание 02CK001-150

Страница 1: ...mbH Co KG P O Box 1260 D 84526 Tittmoning Germany www rosenberger com Tel 49 8684 18 0 Email info rosenberger com Page 1 17 Dieses Dokument ist urheberrechtlich gesch tzt This document is protected by...

Страница 2: ...Kit Documentation 1 4 Calibration Certificate 1 5 2 Specifications Environmental Requirements 2 1 Electrical and mechanical Specifications 2 2 3 Standard Definitions Standard Definitions 3 1 Installa...

Страница 3: ...ed Contributing factors are noise linearity and temperature stability of the VNA transmission and reflection stability of a test port cable as well as operator experience and care VNAs usually offer s...

Страница 4: ...C10S3 1 Calibration load jack 02K150 C10S3 1 Calibration adaptor plug plug 02S121 S20S3 1 Calibration adaptor jack jack 02K121 K20S3 1 Combi wrench 03W008 000 5 mm 6 mm 7 mm 8 mm 9 mm 1 Torque wrench...

Страница 5: ...recautions and information for installing Standard Definitions on a Vector Network Analyzer Calibration Certificate See chapter Calibration Certificate User Manual This document 1 5 Calibration Certif...

Страница 6: ...ns are defined for all calibration standards gauges and the torque wrench in the specific data sheets 3 Standard Definitions 3 1 Standard Definitions Standard definitions provide the data needed to ma...

Страница 7: ...a more complex process Please consult the VNA operating manual Some network analyzers allow a step by step input of the model based standard definitions during the VNA calibration without previously...

Страница 8: ...setting parameters Sweep type linear logarithmic Sweep range start frequency stop frequency Number of points frequency step size Source power IF bandwidth small IF bandwidth basically increases the d...

Страница 9: ...vailable In cases when the two VNA test ports have different connector systems installed e g RPC 3 50 and RPC 2 40 UOSM can handle this situation A second calibration kit is needed Calibration Procedu...

Страница 10: ...calibration or repair contact your local Rosenberger sales office 5 4 Extent of Rosenberger Re Calibration Services Every calibration kit sent for re calibration or repair the following services are...

Страница 11: ...ood connector repeatability and its effect on the overall uncertainty of a measurement procedure should encourage careful inspection interface gauging and handling of coaxial connectors Prior to use a...

Страница 12: ...wear at least a grounded wrist strap and observe correct procedures 6 2 Interface Dimensions and Gauging It is of the utmost importance that connectors do not damage the test equipment interfaces to...

Страница 13: ...or a gauge jack female all gender are vice versa Checking devices for protrusion or excessive recession only a single measurement is sufficient More precise measurements or checking devices very close...

Страница 14: ...es Dokument ist urheberrechtlich gesch tzt This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH Co KG 6 2 4 Gauge blocks Every connector gauge requires a gauge block that is us...

Страница 15: ...in which the centre conductor extends beyond the outer conductor mating plane This may result in buckling of the socket contacts or damage to the internal structure of a device due to the axial force...

Страница 16: ...l centre conductors are within the observed pin depth values in Table 2 2 Refer to 4 2 Interface Dimensions and Gaging 5 Carefully align the connectors The male connector centre pin must slip concentr...

Страница 17: ...en disconnecting a sliding load leave the centre conductor pullback handle in the locked position Use the combi wrench to prevent the device body from turning Use torque wrench to loosen the connectin...

Отзывы: