background image

User Manual 

 

RPC-2.92 Calibration Kit 

02CK001-150 and 02CK010-150

 

02CK001-150 

 

 

Rosenberger Hochfrequenztechnik GmbH & Co. KG  
P.O.Box 1260       D-84526 Tittmoning       Germany 
www.rosenberger.com

 

Tel.    : +49 8684 18-0  
 
Email : [email protected]

 

Page 

 

3 / 17

 

 

D

ie

s

e

s

 D

o

k

u

m

e

n

is

u

rh

e

b

e

rr

e

c

h

tl

ic

h

 g

e

s

c

h

ü

tz

 T

h

is

 d

o

c

u

m

e

n

is

 p

ro

te

c

te

d

 b

y

 c

o

p

y

ri

g

h

 R

o

s

e

n

b

e

rg

e

H

o

c

h

fr

e

q

u

e

n

z

te

c

h

n

ik

 G

m

b

H

 &

 C

o

K

G

 

1.  General Information 

 

This User Manual is valid for the Calibration Kits  

 

02CK001-150 (Full Version) 

 

 

02CK010-150 (Industrial Version)

 

 

Customer specific RPC-2.92 Calibration Kits, excluding Air Line Kits

 

 

The Industrial Version does not contain gauges. So all gauge related chapters are only applicable if 
additional gauges are available, e.g. Rosenberger 03GK0KS-010 or comparable ones. 
For customer specific Calibration Kits all VNA calibration methods may not be available. 

 

1.1 Calibration Kit Normal Use 

 

Calibration Kits are used as an accessory for Vector Network Analyzers (VNA) to perform vector-
error  correction.  Vector-error  correction  is  the  process  of  characterizing  systematic  errors  of  the 
measurement  system  by  measuring  known  calibration  standards,  and  then  mathematically 
removing the effects of these errors from subsequent measurements. The measurement accuracy 
of the calibrated VNA depends mainly on the quality of the calibration kit used. Contributing factors 
are  noise,  linearity  and  temperature  stability  of the  VNA, transmission  and  reflection stability  of a 
test port cable as well as operator experience and care. 

 

VNAs  usually  offer  several  techniques  for  correcting  systematic  measurement  errors.  The 
standards  in  this  calibration  kit  allow  you  to  perform  one-port  OSL  (OSM)  or  two-port  OSLT 
(TOSM) and TRM (TMR) calibrations from DC up to 40 GHz for measurements of components with 
2.92 mm connectors. 

 

Components  with  SMA  and  3.50  mm  connector  are  mechanically  compatible  and  can  also  be 
measured but with reduced accuracy.  

 

1.2 Warnings 

 

The calibration standards and the gauges of this calibration kit are mechanically sensitive devices. 
High accelerations e.g. when falling down will damage them.  

 

Connect the calibration standards only to test ports and other devices that have been cleaned and 
checked  for  gauge,  concentricity  and  integrity  of  the  contact  fingers.  Detailed  procedures  are 
described in Chapter 6 and 7. 

 

Tighten  the  connector  coupling  nuts  to  the  recommended  torque  with  the  torque  wrench.  Do  not 
over torque! 

 

Consider the power applied to the Load calibration standards. Maximum power limits for the sum of 
RF and DC power are defined in the specific data sheets. 

 

It  is  good  lab  practice  to  use  at  least  an  ESD  wrist  strap  when  handling  calibration  standards  or 
DUTs  on  a  VNA  although  the  calibration  standards  themselves  are  not  ESD  sensitive.  Please 
consult your VNA manual. 

 

Follow further limitations given in the specific data sheets.

 

 

Содержание 02CK001-150

Страница 1: ...mbH Co KG P O Box 1260 D 84526 Tittmoning Germany www rosenberger com Tel 49 8684 18 0 Email info rosenberger com Page 1 17 Dieses Dokument ist urheberrechtlich gesch tzt This document is protected by...

Страница 2: ...Kit Documentation 1 4 Calibration Certificate 1 5 2 Specifications Environmental Requirements 2 1 Electrical and mechanical Specifications 2 2 3 Standard Definitions Standard Definitions 3 1 Installa...

Страница 3: ...ed Contributing factors are noise linearity and temperature stability of the VNA transmission and reflection stability of a test port cable as well as operator experience and care VNAs usually offer s...

Страница 4: ...C10S3 1 Calibration load jack 02K150 C10S3 1 Calibration adaptor plug plug 02S121 S20S3 1 Calibration adaptor jack jack 02K121 K20S3 1 Combi wrench 03W008 000 5 mm 6 mm 7 mm 8 mm 9 mm 1 Torque wrench...

Страница 5: ...recautions and information for installing Standard Definitions on a Vector Network Analyzer Calibration Certificate See chapter Calibration Certificate User Manual This document 1 5 Calibration Certif...

Страница 6: ...ns are defined for all calibration standards gauges and the torque wrench in the specific data sheets 3 Standard Definitions 3 1 Standard Definitions Standard definitions provide the data needed to ma...

Страница 7: ...a more complex process Please consult the VNA operating manual Some network analyzers allow a step by step input of the model based standard definitions during the VNA calibration without previously...

Страница 8: ...setting parameters Sweep type linear logarithmic Sweep range start frequency stop frequency Number of points frequency step size Source power IF bandwidth small IF bandwidth basically increases the d...

Страница 9: ...vailable In cases when the two VNA test ports have different connector systems installed e g RPC 3 50 and RPC 2 40 UOSM can handle this situation A second calibration kit is needed Calibration Procedu...

Страница 10: ...calibration or repair contact your local Rosenberger sales office 5 4 Extent of Rosenberger Re Calibration Services Every calibration kit sent for re calibration or repair the following services are...

Страница 11: ...ood connector repeatability and its effect on the overall uncertainty of a measurement procedure should encourage careful inspection interface gauging and handling of coaxial connectors Prior to use a...

Страница 12: ...wear at least a grounded wrist strap and observe correct procedures 6 2 Interface Dimensions and Gauging It is of the utmost importance that connectors do not damage the test equipment interfaces to...

Страница 13: ...or a gauge jack female all gender are vice versa Checking devices for protrusion or excessive recession only a single measurement is sufficient More precise measurements or checking devices very close...

Страница 14: ...es Dokument ist urheberrechtlich gesch tzt This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH Co KG 6 2 4 Gauge blocks Every connector gauge requires a gauge block that is us...

Страница 15: ...in which the centre conductor extends beyond the outer conductor mating plane This may result in buckling of the socket contacts or damage to the internal structure of a device due to the axial force...

Страница 16: ...l centre conductors are within the observed pin depth values in Table 2 2 Refer to 4 2 Interface Dimensions and Gaging 5 Carefully align the connectors The male connector centre pin must slip concentr...

Страница 17: ...en disconnecting a sliding load leave the centre conductor pullback handle in the locked position Use the combi wrench to prevent the device body from turning Use torque wrench to loosen the connectin...

Отзывы: