Rosemount 8712
4-4
Empty Pipe Trigger Level
Limits: 3 to 2000
Configure the threshold limit that the empty pipe value must exceed before
the diagnostic alert activates. Default from the factory is set to 100. For more
detail on this parameter see Appendix C: "Diagnostics".
Empty Pipe Counts
Limits: 5 to 50
Configure the number of consecutive times that the empty pipe value must
exceed the empty pipe trigger level before the diagnostic alert activates.
Counts are taken at 1.5 second intervals. Default from the factory is set to 5.
For more detail on this parameter see Appendix C: "Diagnostics".
Electronics Temperature
Electronics Temperature allows you to view the current value for the
electronics temperature.
Flow Limit 1
Configure the Parameters that will determine the criteria for activating a HART
alert if the measured flow rate falls within a set of configured criteria. This
functionality can be used for operating simple batching operations or
generating alerts when certain flow conditions are met. This parameter can be
configured as a discrete output if the transmitter was ordered with auxiliary
outputs enabled (option code AX), or if this functionality has been licensed in
the field.
Control 1
Turns the Flow Limit 1 ON or OFF.
ON – The transmitter will generate a HART alert when the defined
conditions are met. If a digital output is configured for Flow Limit 1, the
digital output will activate when the conditions for mode 1 are met.
OFF – The transmitter will not generate a HART alert for the Flow Limit 1.
Mode 1
Mode that determines when the Flow Limit 1 HART Alert will activate.
> High Limit – The HART Alert will activate when the measured flow rate
exceeds the High Limit 1 set point.
< Low Limit – The HART Alert will activate when the measured flow rate
falls below the Low Limit 1 set point.
Field Comm.
1, 2, 2, 4, 2
LOI Key
AUX. FUNCTION
Field Comm.
1, 2, 2, 4, 3
LOI Key
AUX. FUNCTION
Field Comm.
1, 2, 2, 5
LOI Key
XMTR INFO
Field Comm.
1, 2, 2, 6
LOI Key
AUX. FUNCTION
Field Comm.
1, 2, 2, 6, 1
Field Comm.
1, 2, 2, 6, 2
Содержание 8712
Страница 2: ......
Страница 4: ......
Страница 26: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 2 16 ...
Страница 84: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 4 46 ...
Страница 102: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 5 18 ...
Страница 114: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 6 12 ...
Страница 131: ...Reference Manual 00809 0100 4664 Rev BA January 2010 B 7 Rosemount 8712 Figure B 1 CSA Installation ...
Страница 132: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 B 8 Figure B 2 Factory Mutual Hazardous Locations ...
Страница 154: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 D 6 ...
Страница 194: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 E 40 ...
Страница 208: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 F 14 ...
Страница 211: ......