Table F-1. Handheld Communicator Diagnostic Messages
Message
Description
Add item for ALL device types or only for this ONE device type
Asks the user whether the hot key item being added should be added
for all device types or only for the type of device that is connected.
Command Not Implemented
The connected device does not support this function.
Communication Error
Either a device sends back a response indicating that the message it
received was unintelligible or the HC cannot understand the response
from the device.
Configuration memory not compatible with connected device
The configuration stored in memory is incompatible with the device to
which a transfer has been requested.
Device Busy
The connected device is busy performing another task.
Device Disconnected
Device fails to respond to a command
Device write protected
Device is in write-protect mode Data can not be written
Device write protected – do you still want to shut off?
Device is in write-protect mode – press YES to turn the HC off and lose
the unsent data.
Display value of variable on hot key menu?
Asks whether the value of the variable should be displayed adjacent to
its label on the hot key menu if the item being added to the hot key menu
is a variable.
Download data from configuration memory to device
Prompts user to press SEND softkey to initiate a memory to device
transfer.
Exceed field width
Indicates that the field width for the current arithmetic variable exceeds
the device- specified description edit format
Exceed precision
Indicates that the precision for the current arithmetic variable exceeds
the device- specified description edit form
Ignore next 50 occurrences of status?
Asked after displaying device status – softkey answer determines
whether next 50 occurrences of device status will be ignored or
displayed
Illegal character
An invalid character for the variable type was entered.
Illegal date
The day portion of the date is invalid.
Illegal month
The month portion of the date is invalid.
Illegal year
The year portion of the date is invalid.
Incomplete exponent
The exponent of a scientific notation floating point variable is
incomplete.
Incomplete field
The value entered is not complete for the variable type.
Looking for a device
Polling for multidropped devices at addresses 1–15
Mark as read only variable on hot key menu?
Asks whether the user should be allowed to edit the variable from the
hot key menu if the item being added to the hot key menu is a variable
No device configuration in configuration memory
There is no configuration saved in memory available to re-configure
off-line or transfer to a device.
No Device Found
Poll of address zero fails to find a device, or poll of all addresses fails to
find a device if auto-poll is enabled
No hot key menu available for this device
There is no menu named “hot key” defined in the device description for
this device.
No off-line devices available
There are no device descriptions available to be used to configure a
device off-line.
No simulation devices available
There are no device descriptions available to simulate a device.
No UPLOAD_VARIABLES in ddl for this device
There is no menu named “upload_variables” defined in the device
description for this device – this menu is required for off-line
configuration.
Содержание 8712
Страница 2: ......
Страница 4: ......
Страница 26: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 2 16 ...
Страница 84: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 4 46 ...
Страница 102: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 5 18 ...
Страница 114: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 6 12 ...
Страница 131: ...Reference Manual 00809 0100 4664 Rev BA January 2010 B 7 Rosemount 8712 Figure B 1 CSA Installation ...
Страница 132: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 B 8 Figure B 2 Factory Mutual Hazardous Locations ...
Страница 154: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 D 6 ...
Страница 194: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 E 40 ...
Страница 208: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 F 14 ...
Страница 211: ......