M
ODEL
755
O
XYGEN
A
NALYZER
6-8
748183-H
Rosemount Analytical
December 1997
-
+
U1
R3
1K
R4
1K
-
+
U2
R17
+15V
-15V
R44
232K
R10
20K
CW
FRONT
PANEL
ZERO
DS1
FEEDBACK
LOOP
BT1
BT2
PHOTOCELL
BOARD
R9
110K
-
+
U2
R1
1K
R2
1K
CR2
R19
10
+15V
-15V
C6
3.3uF
+15V
R18
29.9K
CR1
+
CONNECTOR
BOARD
R91
30.1K
C10
.68uF
R16
56
+15V
-15V
R92
20K
CW
C1
.0022uF
R1
12.4K
R4
50K
FRONT PANEL
SPAN
-
+
U3
R3
R15
4.02K
C10
.68uF
SW1
FRONT
PANEL
%RANGE
C41
1000pf
C3
.47uF
R7
118K
-
+
U1
R8
1.69K
R6
2M
C42
0.01uF
R5
1.78K
C2
.47uF
CONTROL BOARD
R20
20K
R26
1070
PHASE
LEAD
ADJUST
R14
R13
R12
R11
R29
1M
C11
.1uF
0 to 7.5V
the feedback loop and the electronics for that loop. The platinum wires form a fulcrum
around which the test body pivots.
The detector operates in the following fashion. If the sample gas contains oxygen, it
collects in the nonuniform magnetic field around the test body. Oxygen, because of its
paramagnetic qualities, gathers along the magnetic lines of flux and forces the
dumbbell of the test body to be forced out of the magnetic field.
A light source is focused on the test body mirror. As the test body moves out of the
magnetic field. the mirror distributes light unevenly on two photocells (BT1 and BT2).
The photocells create a current proportional to light. This current is converted to a
plus-or-minus (
±
) voltage by U1 and U2, located on the connector board in the
detector housing. This voltage is then presented to comparator U1. The output of U1
goes to U2. The output of U2 causes current to flow through the feedback loop
attached to the dumbbell.
F
IGURE
6-6. D
ETECTOR WITH
F
IRST
S
TAGE
A
MPLIFIER
This feedback current creates an electro-magnetic field that attracts the dumbbell and
mirror into the test assembly magnetic field until the mirror reflects light almost
uniformly on each photocell. A current proportional to the oxygen concentration in the
magnetic field of the test assembly has to be flowing through the feedback loop in
order to maintain balance and provide a reading of the oxygen content of a sample.
Содержание 755
Страница 1: ...Rosemount Analytical MODEL 755 OXYGEN ANALYZER INSTRUCTION MANUAL 748183 H ...
Страница 16: ...MODEL 755 OXYGEN ANALYZER Rosemount Analytical 748183 H November 1997 P 8 NOTES ...
Страница 22: ...MODEL 755 OXYGEN ANALYZER 1 6 748183 H Rosemount Analytical November 1997 NOTES ...
Страница 40: ...MODEL 755 OXYGEN ANALYZER 2 18 748183 H Rosemount Analytical November 1997 NOTES ...
Страница 50: ...MODEL 755 OXYGEN ANALYZER 3 10 748183 H Rosemount Analytical November 1997 NOTES ...
Страница 62: ...MODEL 755 OXYGEN ANALYZER 5 10 748183 H Rosemount Analytical December 1997 NOTES ...
Страница 90: ... blank ...
Страница 92: ... blank ...
Страница 94: ... blank ...