B-3
Model 275 HART Communicator
Figure B-1. HART Communicator Menu
Tree for the Model 3144 and 3244MV.
1 DEVICE SETUP
2 PV
3 AO
4 LRV
5 URV
1 PROCESS
VARIABLE
2 DIAGNOSTICS
AND SERVICE
3 BASIC SETUP
4 DETAILED
SETUP
5 Review
PV—Engineering Units
PV—Percent Range
PV—Analog Output
SV
(TV)
(QV)
Variable Mapping
VARIABLE RE-MAP
1 TEST DEVICE
2 LOOP TEST
3 CALIBRATION
4 Smart Calibration
1 Tag
2 PV Units
3 PV Damp
4 Range Values
5 SENSOR 1 CONN
6 Sensor 1 Sensor s/n
7 SENSOR 2 CONN
8 Sensor 2 Sensor s/n
1 SENSORS
2 SIGNAL
CONDITION
3 OUTPUT
CONDITION
4 Device
Information
1 PV
2 PV Units
3 PV is
4 SENSOR
SETUP
5 SENSOR
LIMITS
6 SENSOR TRIM
1 SENSOR 1
CONFIG
2 SENSOR 2
CONFIG
3 Config Hot
Backup
4 DRIFT
ALERT
5 MISC
CONFIG
1 PROCESS
SENSOR
2 TERM TEMP
SENSOR
3 A/D CONV
INFORMATION
1 Sensor 1 Input
Trim
2 Sensor 2 Input
Trim
3 Snsr 1
Trim-Factory
4 Snsr 2
Trim-Factory
5 SENSOR
CURRENT
1 Sensor 1
Limits
2 Sensor 2
Limits
1 Snsr 1 Conn
2 Snsr 1 Damp
3 Snsr 1 Unit
4 Spc Snsr 1 Con
5 Dis Spc Snsr 1
6 Snsr 1 Snsr s/n
1 Snsr 2 Conn
2 Snsr 2 Damp
3 Snsr 2 Unit
4 Spc Snsr 2 Con
5 Dis Spc Snsr 2
6 Snsr 2 Snsr s/n
1 Term Temp Unit
2 Diff Units
3 Diff Damp
4 Average Units
5 Average Damp
1 Drift Alert Mode
2 Drift Units
3 Drift Limit
4 Drift Damping
5 Drift Alarm Stat.
Active Calibrator
1 Term Temp
2 Term Temp Unit
3 Term Temp
Damp
4 Term Temp
Limits
1 50/60 Hz Filter
1 PV LRV
2 PV URV
3 PV % Range
4 PV Damp
1 ANALOG
OUTPUT
2 HART OUTPUT
3 METER
OPTIONS
4 ALARM
VALUES
5 INTERMITTENT
DETECT
1 Analog Output
2 AO Alarm Type
3 LOOP TEST
4 D/A Trim
5 Scaled D/A Trim
1 Poll Address
2 Num Req Preams
3 Burst Mode
4 Burst Option
1 4 mA
2 20 mA
3 Other
4 End
1 Meter Type
2 Meter Decimal Pt
3 Meter Bar Graph
1 High Alarm
2 Low Alarm
3 High Saturation
4 Low Saturation
1 Intermit Detect
2 Threshold Value
1 PV
2 SV
3 TV
4 QV
1 Differential Temperature
2 Terminal Temperature
3 Sensor 1
4 Sensor 2
5 Sensor Average
1 Status
2 Self Test
3 Master Test
1 4 mA
2 20 mA
3 Other
4 End
1 Apply Values
2 RANGE VALUES
3 SENSOR TRIM
4 D/A Trim
5 Scaled D/A Trim
1 PV LRV
2 PV URV
3 PV Eng. Units
4 PV Low Snsr Lmt
5 PV Upr Snsr Lmt
1 Snsr 1 Input Trim
2 Snsr 2 Input Trim
3 Snsr 1 Trim-Fctry
4 Snsr 2 Trim-Fctry
5 SNSR CURRENT
Active Calibrator
Select Sensor Type
Number of Wires
Any reference to Sensor 2,
Differential Temperature,
Sensor Average, Hot
Backup, Drift Alert, or TV/QV
applies to the use of a Model
275 HART Communicator to
communicate with a Model
3244MV only.
The Review menu lists all of the
information stored in the transmitter.
This includes device information,
measuring element, signal condition,
output condition, and software revision.