Automatic Escalator Deep Cleaning Machine – Rotomac 360
Created by Rosemor International Ltd
Page 23
4.7 Troubleshooting and remedy
Fault
Cause
Remedy
Machine can not be started
Lifting spindles (18) are not in
with AUTOSTART end position
Press LOWER key (6) once
again
Spray nozzle (37) is blocked
Clean spray nozzle (37)
Brushes (24) are soiled
Clean brushes (24)
Machine cleans poorly
Brushes (24) are worn
Replace brushes (24)
Seal strip (22) is defect
Replace seal strip (22)
Suction basin (21) is set
incorrectly
Adjust suction basin (21)
Detergent return to the
machine is too low
Stripping Brush (23) is dirty
Remove suction basin (21)
and clean striping brush (23)
Stripping Brush (23) is dirty
Remove suction basin (21)
and clean stripping brush (23)
Dirt streaks are visible on front
escalator face
Stripping Brush (23) is worn
Remove suction basin (21)
and replace stripping brush
(23)
Attach cover (1)
Water residues on escalator
Cover (1) of dirty-water tank
(2) does not close tight
Replace tank cover (1)
If the fault in the machine can not be
remedied according to the procedures
described in the table above, the customer
service of Rosemor International Ltd should
be notified and the necessary repair work
carried out by its staff.