ULTRAMATRIX REMOTE INSTALLATION AND OPERATIONS MANUAL
31
Switch Installation – Multiple units – “RING” topology
A “RING” configuration is usually used when the users are connected to different UltraMatrix Remotes and need
access to all computers. In a “RING” configuration, users on any KVM station in the ring can access all the
computers in the system on a first-come-first-serve basis.
The connection to the network can be done at this time but it is not necessary to install multiple units.
Figure 16. Ring configuration
The Units in Figure 15 can be any model
The “RING” installation procedure is very similar to installing a “BUS” configuration with the exception of removing
jumper JP1 on the expansion cards on two Units and adding an expansion cable(s) from the first Unit to the last Unit.
This additional expansion cable(s) from the first Unit to the last Unit creates the “RING”.
All Units must be equipped with an expansion card(s).
In the example used in Figure 15, removing jumper JP1 on Unit
#1 and #3 divides the total ring cable length approximately in half.
Unit #3 (IN) to Unit #1 (OUT) = 20’
Unit #3(OUT) to Unit #2 (IN), Unit #2 (OUT) to Unit #1 (IN) = 20’.