SETTING UP
The Rosco V-Hazer should be located on a secure, solid surface such as the floor. The machine can oper-
ate in any orientation from 45 degrees upwards to 45 degrees downwards. Take precautions to avoid
fluid spills if the machine is oriented at an angle.
Fluid Set Up
Only use genuine Rosco V-Hazer Fluid in your V-Hazer. The use of any other fluid will void your warranty, may
damage the equipment, and may cause health hazards.
For convenience, the V-Hazer is designed with an integral compartment that will hold a 4-Litre or 5-Litre
bottle of V-Hazer Fluid. Place the fluid bottle into the compartment. Feed the fluid inlet hose into the bot-
tle of V-Hazer Fluid, ensuring that the filter located at the end of the tube is fully submerged in fluid. Slide
the bottle cap along the tube and tighten the cap onto the bottle. Take precautions to avoid fluid spills.
All Rosco fog and haze machines are primed at the factory with a small amount of fluid. No additional
priming should be necessary for proper haze output. If haze output is diminished or intermittent, see
the Priming the System section of this manual for instructions on how to re-prime the fluid path.
Power Connections
Ensure that the machine is plugged into an outlet rated for the proper voltage and amperage. The
V-Hazer is a 900 watt device and will draw 4A at 230 VAC or 8A at 115 VAC. Note: 230 volt machines are
shipped with bare leads at the end of the power cord. A proper electrical connector must be attached based
on the local power requirements. If unsure how to do this, please contact Rosco or your local Rosco dealer for
assistance. An example of properly wiring a UK 13A connector is shown below.
Earth Wire
Neutral Wire
Outer Insulation
Live Wire
Fuse
Cable grip
- 7 -