background image

- 13 -

MAINTENANCE

Before servicing the Rosco V-Hazer, read and observe all the precautions listed in the Important Safeguards 
section on pages 2-4 of this manual.  Note: Any service that is NOT described in the section below must be  
carried out by a Rosco service technician.  Contact Rosco or your local Rosco dealer for more information on your 
repair and service needs.

Exterior Cleaning 

Excessive dust, fluid residue, and dirt build-up will degrade the performance of the machine and may 
cause overheating to occur.  To maintain adequate air flow and cooling, the outer casing and air vents 
of the machine must be cleaned periodically.  Damage caused by lack of cleaning is not covered by the 
product warranty. 

•  Unplug the machine from power and allow the unit to cool completely before cleaning.  Note:   The  

 

 

output nozzle may remain hot for up to 10 hours after use.

•  Remove dust from the air vents with a soft brush, cotton swab, vacuum or compressed air.
•  Clean any fluid residues from the haze output area of the machine using a damp cloth.
•  Clean the outer casing with a damp cloth only.

Maintaining the Heat Exchanger

The heat exchanger is the core element in a fog or haze machine that transforms fluid into an  
aerosolized fog/haze.  This component operates under extreme temperatures and pressures and 
should be cleaned periodically to ensure optimal performance. The Air-Input Connection was 

 

designed to provide a fast and efficient method of cleaning the heat exchanger by purging it of  
residual fluid and build up using compressed air.   For lasting performance, Rosco recommends purging 
the heat exchanger once a week while in production, and before storing the machine for extended  
periods of time. Rosco does not recommend the use of any purified waters, chemicals or fog machine 
cleaners. Use of these materials will void the warranty. 

Using the Air-Input Connection
You must have a source of compressed air from an air compressor or external air tank available.  
Compressed air must be clean and dry.

Allow the machine to heat until the green Ready Indicator light has illuminated. Using the push-to-con-
nect fitting, connect a ¼” OD tube from your air source by inserting the tube into the Air-Input Connec-
tion located on the rear panel of the machine.   Alternately, you can use a blow gun attachment, or similar 
device with a stepped nozzle, that is held against the orifice of the Air-Input Connection.

Set the air pressure to a maximum of 60 psi.  Higher air pressure may damage the internal plumping 
components.  Blow air into the Air-Input Connection for 30 seconds, or until no additional haze or fluid 
exits the nozzle. 

CAUTION: Keep people and objects at least 3ft (1mv) away from the nozzle of the machine 
during air purging. 

 

To release the tubing from the push-to-connect fitting, push back on the fitting collar and pull to release 
the air line.

Содержание V-Hazer

Страница 1: ...www rosco com V Hazer Fog Machine Operating Instructions READ AND SAVE THESE INSTRUCTIONS...

Страница 2: ...emote Control Panel 8 DMX Control 8 Multi Link 8 Using the Remote Control Panel 8 Using Timers 9 Using DMX Control 9 11 Connecting the DMX 9 Setting the DMX Address 10 DMX Operation 10 11 Using Multi...

Страница 3: ...Rosco V Hazer Fluid All Rosco Fog and Haze Fluids are unique water based formulations that contain no petroleum distillates and are safe when used according to instructions The operating temperature p...

Страница 4: ...machine that shows signs of improper use Even slight damage may be an indication of a major problem If the machine looks questionable use it only under strict observation If the machine shows any unu...

Страница 5: ...e machine switched on for prolonged periods of time without producing haze Do Not Enclose the machine Do Not Install the machine in such a fashion that the operator cannot see the whole machine includ...

Страница 6: ...ff by controlling the flow of power to the unit Air Input Purge Connection This is a push to connect inlet that accepts OD tubing and allows com pressed air to blow through the heat exchanger for clea...

Страница 7: ...led if Standby mode is engaged Fog Level Knob Rotate to set the desired amount of haze output Higher numbers indicate more haze Output is controlled by pump speed increasing and sending more haze flui...

Страница 8: ...ap along the tube and tighten the cap onto the bottle Take precautions to avoid fluid spills All Rosco fog and haze machines are primed at the factory with a small amount of fluid No additional primin...

Страница 9: ...ne on and off using Standby mode and set a repeating timed cycle of on off operation DMX Control from your lighting desk is available as a standard option The V Hazer will use 2 channels of DMX contro...

Страница 10: ...haze before stopping The numeric settings on the timer knobs are relative settings and do not correspond to specific seconds or minutes See the table below for an approximation of the time duration co...

Страница 11: ...fect with its internal fan speed set to maximum and the output volume adjusted to achieve the desired density of haze However with DMX control an effects designer can fully customize the haze effect b...

Страница 12: ...the daisy chain from the remote of the Head Machine to the final machine is 165 feet 50 m Note It is possible to use the Remote Control Panel even when the machine is set up and addressed for DMX Oper...

Страница 13: ...level received via DMX DMX interference due to non terminated signal Raise the DMX level to 11 100 Review the chart in the DMX Operation section of the manual Contact nearest Service Center for repai...

Страница 14: ...re optimal performance The Air Input Connection was designed to provide a fast and efficient method of cleaning the heat exchanger by purging it of residual fluid and build up using compressed air For...

Страница 15: ...rol and programming Control options DMX timer remote DMX channels 2 Fluid system Capacity 120v 4 liters 240v 5 liters Fluid consumption 0 9 liters hour Compatible fluids V Hazer fluid ONLY Connections...

Страница 16: ...15 Dimensions Dimensions are shown in inches and millimeters...

Страница 17: ...ver damage to the Rosco product caused by parts not manufactured distributed or certified by Rosco Rosco is not obligated to provide warranty service should the product fail to be properly maintained...

Страница 18: ...and light Industrial environments 60335 1 2002 A15 2011 Safety of household and similar electrical appliances BS EN 62233 2008 Electromagnetic fields These standards reference the following European s...

Отзывы: