G A L A X Y N A S L X C O N F I G U R A T I O N A N D S Y S T E M I N T E G R A T I O N G U I D E
90
Section 4 Maintenance
•
Using proper ESD procedures, remove the 4 securing screws on the bottom of the
drive.
•
Remove the new hard drive from its wrapper, and with the drive circuit-side-down,
position the connector end so that it is facing the rear of the carrier.
•
Align the holes in the drive to the holes in the drive mounting tray. Insert the provided
screws into the tray and secure the drive.
•
Push the drive tray into the drive bay slot.
•
To reinstall the drive carrier and drive into the bay:
(i) Push the right corner of the tray (not the retention lever) with your thumb
toward the chassis, The retention lever will automatic shift toward the
mounting
tray
slot.
(ii) Push the retention lever to lock in the drive tray.
4.3.2 Replacing a defective internal fan in the GalaxyNASLX2 Chassis
"
Note: If a fan has failed, the system alarm will beep and the FAN Fault LED will
change to RED. In addition the internal fan board will indicate the defective fan with a Fault
LED.
Safety Guidelines
1. Turn off all peripheral devices connected to the server.
2. Turn off the server from the OS or by pressing the power button on the front of the chassis,
then, unplug the AC power cord from the chassis. Disconnect all the peripheral cables and all
network cable connected to the chassis.
Содержание Galaxy LX Series