Galaxy GHDX4 RAID iSCSI-SAS/SATA InstaHardware Reference Manual
82
WARNING! For 3U 16 bay Enclosures
1. When a PSU is removed form the chassis, the cooling module is also
removed from the chassis.
2. It is recommended that the replacement procedure is completed in less
than five (5) minutes to prevent the subsystem from overheating.
Step 5.
For 3U models, to install the replacement module
:
Make sure the extraction handle is held at its up-most
position so that the saddle notches on the sides of the
handle can snap onto the metal anchor pins along the
interior walls of the PSU slot. Push the PSU into
chassis, and when you feel the contact resistance,
push the handle downward to secure the module.
For 4U models, to install the replacement module
:
Make sure the extraction handle is held at its lowest
position so that the saddle notches on the sides of the
handle can snap onto the metal anchor pins on the
interior walls of the PSU slot. Push the PSU into
chassis, and when you feel the contact resistance, pull
the handle upwards to secure the module.