Galaxy GHDX4 RAID iSCSI-SAS/SATA InstaHardware Reference Manual
47
(out of the 0 to 45°C range).
- Battery is not present
OFF indicates that the cache is clean, and
that the battery backup unit is capable of
sustaining memory in case of power
loss.
This signal is local to each controller.
3
Temp.
Amber
ON
indicates that the detected
CPU/board/chassis temperature has
exceeded the higher temperature threshold.
OFF
indicates that the detected temperature
reading is within the preset safe range.
4
CBM Status
Green
/
Amber
Green
steady on indicates the CMB module
is ready. Both a BBU and flash modules are
present. Fast blinking indicates BBU is
charging.
Amber
steady on indicates CBM failure,
meaning either BBU or flash has failed. When
lit, it also indicates either BBU or a flash is
missing in a redundant-controller system.
Blinking
means a BBU is being charged..
5
Hst Bsy
Green
Rapidly Blinking
to indicate traffic on
the host bus.
6
Drv Bsy
Green
Rapidly Blinking
to indicate traffic on
the drive channels.
-
Restore
Default
Green
Lit Green
to indicate the RAID
configuration default has been
successfully restored. The LED state
will be invalidated after a few seconds.
See below for how to use the push
button.
Controller LED Definitions