Device functions
Page 44
RES-5012
Version 2
described in detail in section 8.19 "Error messages" on page 50. Each error code is explained in a tooltip when
you hover over it briefly.
The data can also be exported to a CSV file to enable further processing in another software program. By clicking
on the appropriate button you can select a comma separated format or a semicolon separated format.
The download may take a few seconds, depending on the number of entries which are stored here. The newest
events appear at the top of the list.
If any new events occur while this page is displayed, you do not see them until you refresh the list by clicking on
the "Protocol" menu again.
8.8.5
Graphic page
The temperature controller has an internal memory which can store temperature curves over a period of up to
5 seconds. This memory is automatically filled when the ST bit is set. You can display or export the memory con-
tents on the Graphic page.
By clicking on "Refresh", you cause the graphic data to be downloaded from the memory of the temperature con-
troller and displayed again.
"Clear" clears all data from the memory (disconnecting the 24 VDC supply voltage has the same effect).
The vertical lines mark the beginning of a new heatsealing impulse (ST bit set). A negative set point indicates the
start of a new impulse in the exported data. Cooling processes are not normally visible because they take place
when the ST bit is reset.