Device functions
Version 2
RES-5012
Page 43
The inputs (
section 8.5 "Input data" on page 24) are shown in the left-hand column, the outputs (
"Output data" on page 27) in the middle column, and the current status of all device LEDs (
and controls" on page 21) in the right-hand column.
8.8.3
Parameters / Counters page
This page shows all parameter values received by the temperature controller from the EtherCAT
®
master. If the
parameters have been changed using acyclic services, these changes are also indicated here.
For the meanings of the parameter data, refer to section 8.7 "Object dictionary" on page 30.
Under "Counters" you see a list of all cycle and operating hours counters, which are useful for statistical purposes.
8.8.4
Protocol page
You can download and display the device protocol for the temperature controller on this page. You see the overall
size of the protocol ("Total event entries") as well as the upload progress. All entries appear in the form of a table.
A timestamp (generated by the built-in clock), the operating hours and cycle counters, and the channel selected
at the time are shown for each entry.
In addition to errors, the protocol also contains entries of general interest such as "Clock set" or the AUTOCAL
function. An error code provides information on the cause of all events in the protocol. The error codes are