Device functions
Version 2
RES-5012
Page 33
4005
Diagnosis
RW
on
off (0), on (1)
UINT8
4006
Measurement impulse duration
RW
17
17…30
(1.7…3.0 ms)
UINT8
4007
Data format
RW
Little Endian
(Intel)
Little Endian (Intel)
(0),
Big Endian (Moto-
rola) (1)
UINT8
400A:00
Temperature coefficient
RO
8
UINT8
400A:01
SubIndex 001
RW
1100ppm/K
400…4000ppm/K
UINT16
400A:02
SubIndex 002
RW
1100ppm/K
400…4000ppm/K
UINT16
400A:03
SubIndex 003
RW
1100ppm/K
400…4000ppm/K
UINT16
400A:04
SubIndex 004
RW
1100ppm/K
400…4000ppm/K
UINT16
400A:05
SubIndex 005
RW
1100ppm/K
400…4000ppm/K
UINT16
400A:06
SubIndex 006
RW
1100ppm/K
400…4000ppm/K
UINT16
400A:07
SubIndex 007
RW
1100ppm/K
400…4000ppm/K
UINT16
400A:08
SubIndex 008
RW
1100ppm/K
400…4000ppm/K
UINT16
400B
Temperature range
RW
300 °C
200 °C (0), 300 °C
(1), 400 °C (2),
500 °C (3)
UINT8
400C
Maximum temperature
RW
300 °C
200…500 °C
UINT16
400D
Temperature diagnosis
RW
off
off (0), on (1)
UINT8
400E
Temperature diagnosis delay
(100 ms units)
RW
0s
0…99
(0…9.9 s)
UINT8
400F
Heating up time limit
(100 ms units)
RW
0s
0…999
(0…99.9 s)
UINT16
4010
AUTOCOMP
RW
off
off (0), on (1), auto-
matic (2)
UINT8
4011
Temperature-OK-bit (output 1)
RW
active, if
ACT=SET
off (0),
active, if ACT=SET
(1)
active, if ACT=SET
with latch (2)
UINT8
4012
Hold mode
RW
off
off (0), on (1),
2 seconds (2)
UINT8
4300
System date
RW
UINT32
4301
System time
RW
UINT32
Index:
Sub
index
Name
Acces
s
Default value
1
Range
Data
type