Unit functions
RESM-5
Page 29
205
Temperature range
Various temperature ranges can be selected here.
The temperature range setting permits the RESM-5
to be adjusted to the required operating range. It
also determines the scale that is used for the
progress bar and the analog output.
200°C
300°C
400°C
500°C
206
Max. temperature
This menu step allows you to specify the maximum
permitted temperature measurement in the range
defined with step 205. An error message is output if
this maximum temperature is exceeded.
0 to max. temperature
range (step 205)
213
Key lock
You can specify whether or not the "AUTOCAL"
function can be started with step 107 by pressing
the "ENTER" key.
• No key: The "AUTOCAL" function can be started
by pressing the "ENTER" key.
• AUTOCAL key: The "AUTOCAL" function
cannot be started by pressing the "ENTER" key.
No key
AUTOCAL key
215
Alarm output
This menu step configures the switching behavior of
the alarm output.
• normal: The alarm output (terminal 18) is
energized at alarm.
• inverse: The alarm output (terminal 18) is de-
energized at alarm.
• normal w. RESET: The alarm output
(terminal 18) is energized at alarm or when the
ALARM-IN/RESET input is energized.
• inverse w. RESET: The alarm output
(terminal 18) is de-energized at alarm or when
the ALARM-IN/RESET input is energized.
• 30sec. inactive: The alarm output (terminal 18)
is de-energized for a period of 30 seconds. This
setting is not saved.
• 1min. inactive: The alarm output (terminal 18) is
de-energized for a period of 1 minute. This
setting is not saved.
• 5min. inactive: The alarm output (terminal 18) is
de-energized for a period of 5 minutes. This
setting is not saved.
normal
inverse
normal w. RESET
inverse w. RESET
30sec. inactive
1min. inactive
5min. inactive
225
Temperature unit
Unit for temperature indication and value selection
Celsius
Fahrenheit
226
System time
The current date and time are displayed by the
system clock in real time.
Select the individual values (hours, minutes,
seconds, day, month, and year) by pressing the
ENTER key (the values flash), then press this key
again to store them. The values can be edited using
the "UP" and "DOWN" keys.
No.
Name
Description
Setting range