Startup and operation
RESM-5
Page 21
6. One of the following states then appears:
7. Configure the unit as described in section 8.2 "Unit
configuration" on page 18. The following settings
must always be configured:
8. Run the AUTOCAL function while the heatsealing
band is cold (step 107 in the Settings menu or
"AUTOCAL" signal, terminals 5+14). The progress
of the calibration is indicated by a counter on the
display (approx. 10…15 s). A voltage of 0VDC
additionally appears at the actual value output
(terminals 17+13). If an ATR-x is connected, it
indicates 0…3°C.
When the zero point has been calibrated, the
display returns to the home position and an actual
value of 20°C is indicated. A voltage of 0.66VDC
(300°C range) or 0.4VDC (500°C range, equivalent
to 20°C), appears at the actual value output instead.
If an ATR-x is connected, it must be set to "Z"
(20°C).
If the zero was not calibrated successfully, an error
message indicates error codes 104…106, 211. In
this case the RESM-5 configuration is incorrect
(
section 8.2 "Unit configuration" on page 18 and
ROPEX Application Report). Repeat the zero point
calibration after the unit has been configured
correctly.
9. The fact that the ACTUAL temperature is indicated
on the display (digital value and progress bar)
means the heating and control process can be
observed:
The unit is functioning correctly if the temperature
indicated on the display has a harmonious motion,
in other words it must not jump abruptly, fluctuate, or
deviate temporarily in the wrong direction. This kind
of behavior would indicate that the U
R
measurement
cable has been laid incorrectly.
If an error message is displayed, please proceed as
described in section 9.18 "Error messages" on
page 37.
10.Burn in the heatsealing band (
"Heatsealing band" on page 20) and repeat the
AUTOCAL function.
8.4.2
Restart after replacing the
heatsealing band
To replace the heatsealing band, proceed as described
in section 8.3 "Heatsealing band" on page 20.
Always use a heatsealing band with the
correct alloy, dimensions, and copper plating
in order to avoid malfunctions and overheating.
To prevent dangerous situations, refer to the
risk analysis for the machine or plant.
Continue with section 8.4.1, steps 8 and 9.
DISPLAY
ACTION
Display in home position
Go to step 7
Error message with error code
104…106, 109,
111…113, 211
Go to step 7
Error message with error code
118
Reconnect/
Interchange U
R
measuring wire
to terminals 8+9.
Then return to
step 3
Error message with error code
101…103, 107, 108,
201…203, 801, 9xx
Error diagnosis
(
section 9.18)
Setting
Step in
Configuration
menu
Language
201
Restore factory settings
202
Temperature range and
heatsealing band alloy
204, 205
The RESM is now ready
!
!