Startup and operation
Page 36
RES-430
Version 1
9.7.1
Initial startup
Prerequisites: The controller must be correctly installed and connected (
section 8 "Installation" on page 15).
The possible settings are described in detail in section 9.2 "General controller configuration" on page 21 and
section 10 "Controller functions" on page 38.
The essential controller configurations are described below:
1. Switch off the line voltage and verify that all circuits are deenergized.
2. The supply voltage specified on the nameplate of the controller must be identical to the line voltage that is
present in the plant or machine. The line frequency is automatically detected by the temperature controller in
the range from 47 to 63Hz.
3. Heed the information contained in the ROPEX Application Report as well as the specifications for the heat-
sealing band that is used (section 9.2 "General controller configuration" on page 21).
4. Make sure that a START signal is not present.
5. Switch on the line voltage.
6. A power-up message appears on the display for approximately 2 seconds when the controller is switched on
to indicate that it has been started up correctly.
7. One of the following states then appears:
8. Set the controller configuration as described in section 9.2 "General controller configuration" on page 21. The
following settings are always required:
DISPLAY
ACTION
Display in home position
Error message with error codes
104…106, 111…113, 211,
302, 303
Go to 8
Error message with error codes
101…103, 107, 108,
201…203, 801, 9xx
Fault diagnosis
(
Setting
Step in Con-
figuration
menu
Language
201
Restore factory settings
202
Heatsealing band alloy
203, 204
Temperature range
205
Single/double sealing
240