Startup and operation
Version 1
RES-430
Page 27
of the SET temperature. This value can be set between 40 and 100%.
The factory setting is 40%.
3.
"Cooling time in s" (if setting with menu step 210 = "Time")
The cooling phase ends when the specified time elapses. This time can be set between 0 and 99.9s.
The factory setting is 10.0s.
9.3.6
Setting the start of the heatsealing time
The start condition for the set heatsealing time (step 104 in the Settings menu) can be specified with step 211 in
the Configuration menu.
The following settings are possible:
1.
"When heating starts"
The parameterized heatsealing time starts as soon as the set starting delay elapses (
Settings menu,
step 103).
If the starting delay = 0s, the heatsealing time begins as soon as the "START" signal is activated.
2.
"When temperature reached" (Factory setting)
Once again, the heating process starts as soon as the set starting delay elapses (
Settings menu, step 103).
The specified heatsealing time does not start, however, until the ACTUAL temperature of the heatsealing band
reaches 95% of the SET temperature.
These two alternatives are shown below:
9.3.7
Relay K1 / solenoid drive (optional)
The function of relay K1 (or the optional solenoid drive) is specified with step 212 in the Configuration menu.
The settings can be selected as follows (as of software revision 007):
1.
"When start signal present" (Factory setting)
ACTUAL
temp.
START
signal
ON
T
t
t
0
0
95% of set point
When
heating
t
0
Start of
heatsealing time
starts
When
temperature
t
0
reached
Heatsealing time
Heatsealing time