Startup and operation
Page 34
RES-430
Version 1
9.5.4
Temperature sensor
The maximum permissible temperature of the sensor can be set with step 246 (assuming the temperature sensor
has been activated with step 241). An alarm is immediately output by the controller if this maximum temperature
is exceeded.
If a heatsealing cycle is in progress, it is interrupted. The temperature monitoring function is activated 3s after the
controller is switched on.
If a temperature sensor is not connected (or if the sensor connecting cable is defective), an alarm is output by the
controller after 3s (assuming the temperature sensor has been activated with step 241).
The sensor temperature measurement described here serves to monitor and/or limit the load cell or
machine temperature. It cannot be used to monitor the temperature of the heatsealing band or for
temperature control.
Upper range limit
exceeded
(measured
value > 12.2mV)
" HHHHH "
814
Load cell not con-
nected
" ***** "
820
Measured force
Indication
on display
Error code
(if force
diagnosis
is active)
RES-430
26
Temp.
sensor
0V
27
ϑ
Maximum
Temperature
Time
Error message
sensor temp.
0
!