![Ronetix PEEDI Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/ronetix/peedi/peedi_user-manual_1485040087.webp)
Using PEEDI
Description:
Telnet backspace character ASCII code.
Example:
[TELNET]
PROMPT = "peedi> "
BACKSPACE = 127
Section DISPLAY
These sections parameters specify the brightness of the seven segment LED indicator and the
volume of the speaker, both accept values in the range 0 - 100.
VOLUME
Synopsis:
VOLUME = 0 .. 100
Description:
Speaker volume
Example:
[DISPLAY]
VOLUME=0 - disable beeper
VOLUME=100 - enable beeper
Section ACTIONS
Declares what scripts can be executed using front panel buttons, each declaration must be on a new
line. The declaration consists of a number associated with the specified script name. A section with
the same name must exist somewhere in the target configuration file. If AUTORUN=N parameter is
specified, where N is number of a script, the given script will be executed every time a target is
connected to PEEDI. For more information see Script execution using the front panel interface .
Example:
PEEDI User’s Manual
87