Using PEEDI
WAKEUP_TIME
Synopsis:
WAKEUP_TIME = <milliseconds>
Description:
Time to delay the JTAG operations after target power up is detected.
TIME_AFTER_RESET
Synopsis:
TIME_AFTER_RESET = <milliseconds>
Description:
Time to delay the JTAG operations after RESET is released.
DBGREQ_OUTPUT
Synopsis:
DBGREQ_OUTPUT = HIGH|LOW
Description:
Define the state of the JTAG DBGREQ line.
COREn
Synopsis:
COREn = CORE_TYPE, [<tap_num>]
Description:
Type of CORE and a TAP number separated by comma. Every core must be defined
with the COREn parameter, where ’n’ is a number; each parameter related to this core
must be preceded with the same COREn prefix.
PEEDI User’s Manual