44
LAN/RS-232 Command Reference
LAN Interface
This uses the CONTROL port on the V-600UHD.
You use Telnet to operate the V-600UHD remotely over a LAN
(TCP/IP protocol).
Communication standards
Port
CONTROL port (LAN)
Protocol
TCP
Port number
8023
Setting the IP address of the V-60HD
1.
Select the [MENU] button
&
“System”
&
“LAN Control,” and press the [VALUE] knob.
2.
Select “IP Address,” and use the [VALUE] knob to set
the IP address.
&
Details on menu items: see p. 42.
3.
Press the [MENU] button to quit the menu.
Verifying the LAN information
1.
Select the [MENU] button
&
“System”
&
“LAN Control,” and press the [VALUE] knob.
2.
Select “Information,” and press the [VALUE] knob.
3.
Press the [MENU] button to quit the menu.
RS-232 Interface
RS-232 connector pin layout
Pin assignments
1 2 3 4 5
6 7 8 9
DB-9 type (male)
Pin No.
Signal
1
N.C.
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
N.C.
Communication standards
Communication method
Synchronous (asynchronous), full-duplex
Communication speed
9,600 bps/38,400 bps
Parity
none
Data length
8 bits
Stop bit
1 bit
Code set
ASCII
Flow control
XON/XOFF
Cable wiring diagram
Use an RS-232 crossover cable to connect the V-600UHD and the
controller (an RS-232-compatible computer or other device).
V-600UHD
Controller
N.C.: 1
1:
RXD: 2
2: RXD
TXD: 3
3: TXD
DTR: 4
4:
GND: 5
5: GND
DSR: 6
6:
RTS: 7
7:
CTS: 8
8:
N.C.: 9
9:
(Crossover connection)
* The connections between 4 and 6 and between 7 and 8 are inside
the V-600UHD.
Command Format
Commands are formatted using the configuration shown below.
Commands are all in ASCII code.
stx Command code
: Parameter
,
Parameter
;
stx
ASCII code “02H” is a control code indicating the start of a
command. “H” indicates that it is a hexadecimal value.
Command code
This specifies the command type (3 letters of the alphabet).
Parameter
This is appended to a command that requires one or more
parameter. The command and the parameter portion are
separated by a “ : ” (colon). When there are multiple parameters,
they are each separated by “ , ” (comma) characters.
;
This is the code that the V-600UHD recognizes as the end of a
command.
* The codes of stx (02H), ACK (06H), and XON (11H)/ XOFF (13H) are
the control codes.
V-600UHD support two types of remote-interface communication: LAN and RS-232.
Using the CONTROL port (LAN) or RS-232 connector to send specific commands to the V-600UHD from a controlling device lets you operate the
V-600UHD remotely.