5. Maintenance
How to Replace the Separating Knife
If the separating knife becomes dull, replace it with the included replacement blade.
1
Press the [MENU] key, then press the [ ] key
to select [REPLACE KNIFE].
2
Press the [ENTER] key.
When the screen shown in the figure appears, the print-
ing carriage moves to the left.
3
Open the front cover, then remove the separat-
ing knife.
4
Replace with a new knife.
The knife is secured in place by the magnet.
5
Install the separating knife.
6
Close the front cover and press the [ENTER]
key.
Do not touch the tip of the separating knife with your fingers.
Doing so may result in injury.
Do not touch the operation panel while replacing the separating knife is in progress.
The cutting carriage may move and cause injury.
If the blade remains in the cutting carriage, use the
tweezers in the cleaning kit to remove it.
1) Loosen the screw until it slips out.
2) Grasp the screw portion, and slowly
pull it out in the direction of the arrow.
When doing this, do not pull it back
toward you.
Positioning
groove
1
2
1) Grasp the screw portion and slowly insert it
into the groove.
2) Tighten the screw.
Take care to ensure that the knife does not
slip out of position at this time.
1
2
5-4 Replacing the Consumable parts
MENU
REPLACE KNIFE
FINISHED?