Adjustment parameter 2:
Selection of sensor test.
Fig. 70: Selection of sensor test
Possible choices:
• no: No sensor test will be performed.
• yes:
The operator will be requested to remove all sheets. Then the system performs the
sensor test. If the test was done error-free, “Sensor distance OK“ is displayed. If the
test shows faulty results, “Sensor distance too small” or “Sensor distance too large”
will be shown. Then the sensor distance should be checked / corrected.
Adjustment parameter 3:
Indication of the deviation of the sensor distances found.
Fig. 71: Sensor distances
By pressing the ENTER key the deviation of the investigated sensor distances are indicated (when
in „change“ mode).
Fig. 72: Indication of deviation of sensor distances
Adjustment parameter 4:
Calculation of the sensor distances.
Fig. 73: Scheduled parameter
By pressing the ENTER key the distance is calculated (in mm / inch).
Adjustment parameter 5:
Control of sensors.
Fig. 74: Control of sensors
Possible choices:
• no: The sensor allocation will not be tested.
• yes:
The sensors are checked for correct wiring / allocation.
In case of fault-free test result „Sensor control OK“ will be shown.
Adjust Parameter: 2
test Sensor distance
no
Adjust Parameter: 3
deviation distance
Adjust Parameter: 3
OK range:-200...+200
A1: 79 A2: 82
A3: 80 A4: 85
Adjust Parameter: 4
distance sensors
Adjust Parameter: 5
control sensors
no