Manual
Double Sheet Detector-series I20
B0069991 / Rev. 1.7
Start-up
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
73
7.4.2.2 Sub structure “Program parameters” of the operating mode “Frequency”
(Monitoring Parts for Hardened / Tempered Properties and Materials Mix up)
Fig. 32: Sub structure „program parameters“ of the operating mode Frequency
Program No.
1 … 255
Lower limit value TL
TL% (0-99%) and absolute
Upper limit value TU
TU% (100-180%) and absolute
Sensor number
Sensor number
1 / 2 / 3 / 4 / 1+2 / 1+3 / 1+4 / 2+3 / 2+4 / 3+4 /
1+2+3 / 1+2+4 / 1+3+4 / 2+3+4 / 1+2+3+4
Frequency
8 Hz - 25 KHz
Teach-in part A
– ok
– missing
– dynamic all / single
– static all / single
Teach-in part B
– no
– dynamic all / single
– static all / single
Material
not available
Settling time desired / actual
2 / 4 / 8 / 15 / 25 / 100 / 250 ms
(depending on sensor type)