Program parameter 5:
Setting the percentage threshold of the lower limit value.
Fig. 56: Adjusting the upper limit
Value range: between 0% and 99%
Program parameter 6:
Setting the percentage threshold of the upper limit value.
Fig. 57: Adjusting the lower limit
Value range: between 100% and 180%
Program parameter 7:
Adjusting the nominal settling time and indicating the actual settling time.
Fig. 58: Adjusting the nominal settling time
In the upper line the „desired value“ of the settling time must be entered. If the achievable settling
time exceeds the „desired value“, the system selects the next larger possible value and indicates
this value in the line below.
Possible choices:
• 2 / 4 / 8 / 15 / 25 / 100 / 250 ms
In general, the „desired value“ should be set such that it fits the transportation speed and the sheet
length.
• Fast transportation and short sheets require shorter measurement times
Program parameter 8:
Teach-In for Part A
Fig. 59: Status of Teach-In Part A
Possible indications:
• missing: A Teach-In for Part A has not been performed
• OK:
A Teach-In for Part A was already performed
• static:
A static Teach-In for Part A will be performed
• dynamic: A dynamic Teach-In for Part A will be performed
Program Parameter: 5
lower threshold
80%
Program Parameter: 6
upper threshold
120%
Program Parameter: 7
settling time I20
desired value:250ms
actual value: 250ms
Program Parameter: 8
Teach-In part A
ok