Technical data
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
15
Fig. 4: Dimensions of IS/IE sensors
bis SE75.wmf
2.5
Sensor cables
Cable marking:
The cables have quick disconnects at both ends. The plug at the control unit side is always
straight.
SCI20S-GG
with straight cable socket at the sensor
SCI20S-GW
with right angle cable socket at the sensor
SCI20S-GG-TE extension cable for sensor cable (also use as quick disconnect)
Applicable to all cables:
Bending radius:
50 mm at fixed installation
100 mm at flexible installation
Cable diameter:
7.1 mm
Suitable for drag chains, oil-proof, PUR jacket
Superflex Tronic(C)PUR TP 4 x 2 x 0.25 mm²
Note
The sensor cable is an active component of the sensor technology.
The technical data of the sensors is valid only if the cable specification is
met. A shielded cable must be used.
The cable length can be to up to 50 m. Following the rule "the shorter the