5 | Assembly of the Centric Clamp
24 / 43
KZS-P_KZS-PG
The following assembly instructions describe the general procedure for as-
sembly of the centric clamp on a suitable assembly surface. The assembly
surface and the lines must be suitably prepared for the individual centric
clamp.
§
The machine is switched off and protected against being switched on
again.
1.
Check the machine table and the underside of the centric clamp for un-
evenness and microswarf and fix the latter if necessary.
2.
Depending on the connection type, remove the seals of the connections
on the body (see
table “Remove seals of the connections”
).
3.
Place the centric clamp on the assembly surface to test it. The body
must lie completely and flatly on the surface.
4.
Depending on the prepared type of positioning, use clamping sleeves or
cylindrical pins (see
table “Position centric clamp”
).
5.
The alignment of the centric clamp can be checked by measuring via the
ground flanks on the side of the body.
6.
Grease the fixing screws in the thread area and on the head contact sur-
face.
7.
Tighten the fixing screws with the permissible tightening torque (see
Checking the Tightness of Screw Connections [
).
Ø
The centric clamp is assembled and connected.
8.
Check clamping force (see
)
ü
The centric clamp is ready for operation.
Содержание KZS-P
Страница 2: ......