Maintenance | 7
KZS-P_KZS-PG
37 / 43
Central lubrication
Recommended oil
Lubricating oil
G CLP DIN 51517-3:2014-02
Viscosity class
VG 220 DIN ISO 3448:2010-02
Temperature
Max. 70 °C
Construction size
Oil quantity [per connection]
64
2 cm³
100
2 cm³
160
4 cm³
200
6 cm³
250
8 cm³
4
4
The central lubrication connections (4) are sealed in the factory with threaded
pins. For central lubrication,
§
the threaded pins are removed from the cover,
§
the boreholes are sealed with O-rings and
§
both
supply lines are connected.
1.
Pour in the oil (for oil quantity, see
Table
) via
both
connections of the
central lubrication unit (4) on the underside of the base body.
Ø
Each connection supplies a guide of both base jaws, for which reason
both
connections must be connected.
2.
Move through the complete stroke several times.
Ø
The oil is distributed.
Ø
After 400 clamping cycles, move through the complete stroke again at
least twice.
ü
The centric clamp is lubricated.