Interval
Checking the Clamping Force.
See
.
Monthly
or at the latest after 10,000 clamping
cycles.
Complete cleaning (maintenance, ba-
sic cleaning and replacement of wear
parts).
See
Depending on conditions of use and
use of coolant after approx. 2000 hrs.
or at the latest after 100,000 clamping
cycles.
7.3
Maintenance Work
7.3.1
Checking the Tightness of Screw Connections
If screws are replaced or undone, incorrect replacement or incorrect attach-
ment may lead to dangers for persons and objects. For this reason, for all
holding screws, the screw recommended by the manufacturer of the screw
must be used and the tightening torque applied in accordance with the screw
quality.
For
cylinder head screws
of the conventional sizes M4 – M24 and strength
classes 8.8, 10.9 and 12.9, the following tightening torque table applies:
Tightening torque in Nm
Strength
class
M4 M5 M6
M8
M10 M12 M14 M16 M18 M20 M22 M24
8.8
3.0 5.9 10.1 24.6 48
84
133 206 295 415 567 714
10.9
4.6 8.6 14.9 36.1 71
123 195 302 421 592 807 1017
12.9
5.1 10 17.4 42.2 83
144 229 354 492 692 945 1190