Remote control commands
R&S
®
RTB2000
468
User Manual 1333.1611.02 ─ 11
Parameters:
<MosiSource>
CH1 | CH2 | CH3 | CH4 | D0..D15
*RST:
CH1
Manual operation:
See
BUS<b>:SPI:MISO:SOURce
<MisoSource>
Selects the input channel of the optional MISO line.
Suffix:
<b>
.
1, bus 2 is not available if the MISO source is used.
Parameters:
<MisoSource>
CH1 | CH2 | CH3 | CH4 | NONE | D0..D15
*RST:
NONE
Manual operation:
See
BUS<b>:SPI:DATA:POLarity
<Polarity>
Selects whether transmitted data is high active (high = 1) or low active (low = 1) on the
data line.
Suffix:
<b>
.
1 | 2
Parameters:
<Polarity>
POSitive | NEGative
POSitive = high active
NEGative = low active
*RST:
POSitive
Manual operation:
See
BUS<b>:SPI:MOSI:POLarity
<MosiPolarity>
Selects if transmitted data is high active (high = 1) or low active (low = 1) on the MOSI/
MISO line.
Suffix:
<b>
.
1 | 2
Parameters:
<MosiPolarity>
ACTLow | ACTHigh
*RST:
ACTH
Manual operation:
See
Serial bus analysis