Noise-Limited OTA Performance in Transmit Diversity Mode
R&S
®
AMS32-K31
13
User Manual 1175.6678.02 ─ 01
The "Target Value" is the BLER at which the sensitivity level is reached. The test case
specification stipulates a 10 % target value.
Click "OK" to confirm your settings and return to the "OTA Auto Test Template" dialog.
2.1.2.4
Fading Settings
The "Fading Settings" dialog shows the parameters of the static channel model that the
R&S CMW500 uses for the MIMO tests. "Static Channel Model with Communication
Tester" must be selected for MIMO OTA tests.
MIMO OTA test cases and fading
The Rohde & Schwarz MIMO OTA test cases do not require a faded downlink LTE signal.
The settings described in this section have been added to support further investigations.
Access:
"Fading Settings" button in the "OTA Auto Test Template" dialog; see
Configuration